Image may be a different model in this range and is for illustration purposes only

40-525-001 Range

PXI Single 32x4 2-Pole

An updated version available - see 40-525A-001

40-525-001

Sorry, estimated shipping time unavailable

Volume pricing

Excludes tax & import fees

 

Overview

The 40-525 is a 32x4 matrix with switched loopthru on its X and Y buses. This “FlexBus” architecture has been primarily developed for the automotive test industry, and for ECU testing in particular. The X bus connects to the inputs and outputs of the ECU under test and is also fed to the LX connections via isolation switches. The LX connections enable easy access to digital I/O circuitry.
The Y bus can be switched to any X signal and can be used for connecting test voltages, loads or fault conditions to the ECU’s signals. This makes the X40- 525 the ideal high density solution for rigorous fault testing or burn-in applications.


Key Features

  • 32x4 Matrix With Switched Loop-Thru for Simplified Connection of Digital I/O
  • Suitable for Automotive ECU Test Applications
  • High Density Low Cost Solution
  • 2A Hot or Cold Switching
  • Switch up to 300VDC/250VAC and up to 60W Max Power
  • VISA/IVI Drivers Supplied for Windows XP/Vista/7/8
  • Supported by PXI or LXI Chassis
  • 3 Year Warranty
 

Downloads

 

Specifications

Switch Type
EMR
Max I (A)
2
Max V DC
220
Poles
2
Banks
1
X Size
34
Y Size
4
Years

Warranty