High-Voltage LXI Matrix Modules

Our high-voltage LXI matrices are ideal for applications where a simple start-up process is needed and for applications requiring control over large distances.

Two types of  high-voltage matrices are available:

  • 2-pole 75x4 matrix modules with one, two or three separate 75x4 matrices housed in the same case (model 60-311) . Capable of cold switching 750VDC continuous with a carry current of 2A plus higher pulse conditions e.g. typically 1000VDC for 1s with low duty cycle or 6A for 200us with <1% Duty Cycle. Front panel Loop-Thru connections allow a 75x4 matrix to be easily expanded to an adjacent matrix in the same case. Also, expansion can be carried out between 60-311 matrices in separate cases. 
  • 2-pole matrix modules available in 300x2, 200x2 and 100x2 formats (model 60-310). Capable of cold switching 1000VDC and has a maximum carry current of 1A – they are designed for high voltage applications including circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.

Select modules are supported by our eBIRST Switching System Test Tools, these tools provide a quick and simple way of finding relay failures within LXI, PCI and PXI switch systems. 

Standard 3-Year Warranty

These matrices are supported by a comprehensive range of cable and connector accessories  and come with a standard 3-year warranty.

The table below will help you choose the appropriate version for your application:

  HIGH VOLTAGE MATRICES
Type Current Switch Type Max
Voltage
Max
Power
Banks Configuration Connector Part No.
2 Pole 1A Reed 1000VDC
10W 1 100 x 2 50W and
9W HV D-Type 
60-310-102
200 x 2 60-310-202
300 x 2 60-310-302
1A (2A) EMR 1000VDC 30W 1 75 x 4 60-311-001
2 75 x 4 60-311-002
3 75 x 4 60-311-003
6 Products
Untitled Button