PXI Fault Insertion Matrix Modules
Electro-mechanical Relay for Current Handling up to 10 Amps
- Breakout Connections for Wiring to Sensors
- Pickering BRIC Architecture Provides Scalable Matrix Size
- Wide Range of Matrix Sizes & Partially Populated Configurations Available
- Ruthenium Reed Relay for Maximum Signal Performance
- Electro-mechanical Relay for Current Handling up to 10 Amps
- Occupy four or eight 3U PXI Slots
- Kernel, VISA and IVI Support for PXI Environments & Kernel and IVI Support For LXI Environments
- Selected modules are supported by our eBIRST Switching System Test Tools, these tools provide a quick and simple way of finding relay failures within LXI, PCI and PXI switch systems.
Take a look at our video:
Automated Fault Insertion and its Role in Hardware-in-the-Loop (HIL) Simulation
All of our fault insertion matrices feature a breakout arrangement that allows faults to be attached to the sensor lines
via the Y axis. This includes the breaking of a connection or the adding of a series defect – all of which can simulate
connectivity problems in the system. The three pin breakout versions allow the connection to be swapped for a “bad” sensor
simulation.The use of a programmable matrix for fault insertion ensures testing is fast to perform and can be reproduced
on subsequent test cycles in the event of corrective action or a system upgrade.
We also offer mating cables and connectors for these modules to ensure speedy and successful system integration.