Resistance Temperature Detectors (RTD) Simulators

Simulation of resistance based temperature sensors such as positive or negative temperature coefficient thermistors. Resistance Temperature Detectors (RTDs) can be wire-wound or thin film. Our RTD simulator modules provide a cost-effective method of simulating both PT100 and PT1000 RTD sensor types that require fine setting resolution.

We also offer mating cables and connectors. For additional information please take a look at our support knowledgebase or feel free to contact us.

Resistance Temperature Detector (RTD) Simulator Modules | Pickering
Untitled Button
Channels
Channel Type
Max R (Ω)
Resolution (Ω)
Accuracy (%)
Min R (Ω)
Price

40-263-201

PXI RTD Simulator Module, 16 Channel, PT100

A 3U PXI module that supports 16-channels of 40Ω to 900Ω PT100 RTD simulation

Channels
16
Channel Type
Resistor
Max R (Ω)
900
Resolution (Ω)
0.01
Accuracy (%)
0.1
Min R (Ω)
40
Product Type
Programmable Resistors
Platform
PXI
Power (W)
0.1
€11,920

40-263-202

PXI RTD Simulator Module, 16 Channel, PT500

A 3U PXI module that supports 16-channels of 200Ω to 4500Ω PT500 RTD simulation

Channels
16
Channel Type
Resistor
Max R (Ω)
4500
Resolution (Ω)
0.05
Accuracy (%)
0.1
Min R (Ω)
200
Product Type
Programmable Resistors
Platform
PXI
Power (W)
0.1
€11,920

40-263-203

PXI RTD Simulator Module, 16 Channel, PT1000

A 3U PXI module that supports 16-channels of 400Ω to 9000Ω PT1000 RTD simulation

Channels
16
Channel Type
Resistor
Max R (Ω)
9000
Resolution (Ω)
0.1
Accuracy (%)
0.1
Min R (Ω)
400
Product Type
Programmable Resistors
Platform
PXI
Power (W)
0.1
€11,920

Filter

Channels

The number of discrete channels in a single topology.

Channel Type

The topology of each channel

Max R (Ω)

Maximum resistance each channel may be programmed to

Resolution (Ω)

Smallest discrete setting step for each resistance channel

Accuracy (%)

The accuracy of programmed resistance

Min R (Ω)

Minimum resistance each channel may be programmed to

Loading