LXI High-Density Matrix

Our LXI High-Density Modules are single and double pole matrices available in a wide range of configurations, including versions with the added flexibility of a dual analog bus. These high-density matrices are ideal for signal routing in large automatic test equipment (ATE) systems including, semiconductor test. They are suitable for applications where a simple start-up process is required and for applications requiring control over large distances.

Selected modules are supported by our Diagnostic Test Tools, BIRST (Built-In Relay Self-Test) and eBIRST Switching System Test Tools; these tools provide a quick and simple way of finding relay failures within LXI, PCI and PXI switch systems.

All of our LXI matrices are designed in accordance with the LXI Standard 1.4. They are supported by a comprehensive range of cable and connector accessories.

LXI High Density Matrix | Pickering Interfaces
Untitled Button
Product Type
Switch Type
Max I (A)
Max V DC
Poles
Banks
X Size
Y Size
Price

60-551-022

LXI High Density 128x4, 2A Matrix - 60-551-022

High-density single pole matrix module suitable for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
128
Y Size
4
Platform
LXI
Function
Matrix
$19,308

60-551-023

LXI High Density 192x4 Matrix - 60-551-023

High-density single pole matrix module suitable for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
192
Y Size
4
Platform
LXI
Function
Matrix
$24,456

60-553-002

LXI High-density 256x4, 2A Matrix

High-density single pole matrix module for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
150
Poles
1
Banks
1
X Size
256
Y Size
4
Platform
LXI
Function
Matrix
$24,978

60-556-023

LXI High Density 192x4 2-Pole 2A Matrix With BIRST

High-density double pole matrix suitable for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
2
Banks
1
X Size
192
Y Size
4
Platform
LXI
Function
Matrix
$29,346

60-551-024

LXI High Density 256x4 Matrix - 60-551-024

High-density single pole matrix module suitable for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
256
Y Size
4
Platform
LXI
Function
Matrix
$30,246

60-551-025

LXI High Density 320x4 Matrix - 60-551-025

High-density single pole matrix module suitable for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
320
Y Size
4
Platform
LXI
Function
Matrix
$35,010

60-553-003

LXI High-density 384x4, 2A Matrix

High-density single pole matrix module for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
150
Poles
1
Banks
1
X Size
384
Y Size
4
Platform
LXI
Function
Matrix
$35,856

60-556-024

LXI High Density 256x4 2-Pole 2A Matrix With BIRST

High-density double pole matrix suitable for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
2
Banks
1
X Size
256
Y Size
4
Platform
LXI
Function
Matrix
$36,288

60-551-026

LXI High Density 384x4 Matrix - 60-551-026

High-density single pole matrix module suitable for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
384
Y Size
4
Platform
LXI
Function
Matrix
$39,546

60-556-025

LXI High Density 320x4 2-Pole 2A Matrix With BIRST

High-density double pole matrix suitable for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
2
Banks
1
X Size
320
Y Size
4
Platform
LXI
Function
Matrix
$41,994

60-553-004

LXI High-density 512x4, 2A Matrix

High-density single pole matrix module for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
150
Poles
1
Banks
1
X Size
512
Y Size
4
Platform
LXI
Function
Matrix
$43,494

60-551-027

LXI High Density 448x4 Matrix - 60-551-027

High-density single pole matrix module suitable for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
448
Y Size
4
Platform
LXI
Function
Matrix
$43,548

60-551-028

LXI High Density 512x4 Matrix - 60-551-028

High-density single pole matrix module suitable for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
512
Y Size
4
Platform
LXI
Function
Matrix
$46,800

60-556-026

LXI High Density 384x4 2-Pole 2A Matrix With BIRST

High-density double pole matrix suitable for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
2
Banks
1
X Size
384
Y Size
4
Platform
LXI
Function
Matrix
$47,460

60-553-005

LXI High-density 640x4, 2A Matrix

High-density single pole matrix module for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
150
Poles
1
Banks
1
X Size
640
Y Size
4
Platform
LXI
Function
Matrix
$52,248

60-556-027

LXI High Density 448x4 2-Pole 2A Matrix With BIRST

High-density double pole matrix suitable for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
2
Banks
1
X Size
448
Y Size
4
Platform
LXI
Function
Matrix
$52,266

60-556-028

LXI High Density 512x4 2-Pole 2A Matrix With BIRST

High-density double pole matrix suitable for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
2
Banks
1
X Size
512
Y Size
4
Platform
LXI
Function
Matrix
$56,154

60-553-006

LXI High-density 768x4, 2A Matrix

High-density single pole matrix module for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
150
Poles
1
Banks
1
X Size
768
Y Size
4
Platform
LXI
Function
Matrix
$61,368

60-553-007

LXI High-density 896x4, 2A Matrix

High-density single pole matrix module for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
150
Poles
1
Banks
1
X Size
896
Y Size
4
Platform
LXI
Function
Matrix
$66,030

60-553-008

LXI High-density 1024x4, 2A Matrix

High-density single pole matrix module for signal routing in large ATE systems. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Product Type
Matrices
Switch Type
EMR
Max I (A)
2
Max V DC
150
Poles
1
Banks
1
X Size
1024
Y Size
4
Platform
LXI
Function
Matrix
$72,468

Filter

Product Type

Switch topology or Pickering's programmable resistor products

Switch Type

EMR - Electro-Mechanical Relay, cost-effective, medium power switching. Reed - reed relays, excellent low-level switching, fast, long life. Solid-State - very fast, indefinite life, high power switching, but high leakage and insertion loss.

Max I (A)

Maximum continuous current each switch can carry.

Max V DC

The maximum voltage that may be applied to each switch.

Poles

The number of common terminals simultaneously switched by a single operation. … more

Banks

The number of independent switch topologies on a single module.

X Size

The number of matrix columns, used with Y Size to specify the size of a cross-point matrix.

Y Size

The number of matrix rows, used with X Size to specify the size of a cross-point matrix.

Loading