PXI Fault Insertion Matrix Modules
- Breakout Connections for Wiring to Sensors
- Pickering BRIC Architecture Provides Scalable Matrix Size
- Wide Range of Matrix Sizes & Partially Populated Configurations Available
- Ruthenium Reed Relay for Maximum Signal Performance
- Electro-mechanical Relay for Current Handling up to 10 Amps
- Occupy four or eight 3U PXI Slots
- Drivers Supplied for Windows and Linux, Plus Support for Real-time Systems
- Selected modules are supported by our eBIRST Switching System Test Tools, these tools provide a quick and simple way of finding relay failures within LXI, PCI and PXI switch systems.
Take a look at our video:
Automated Fault Insertion and its Role in Hardware-in-the-Loop (HIL) Simulation
All of our fault insertion matrices feature a breakout arrangement that allows faults to be attached to the sensor lines
via the Y axis. This includes the breaking of a connection or the adding of a series defect – all of which can simulate
connectivity problems in the system. The three pin breakout versions allow the connection to be swapped for a “bad” sensor
simulation.The use of a programmable matrix for fault insertion ensures testing is fast to perform and can be reproduced
on subsequent test cycles in the event of corrective action or a system upgrade.

We also offer mating cables and connectors for these modules to ensure speedy and successful system integration. We stand behind our products with a three-year warranty.
The tables below will help you to choose the appropriate module for your application.
FAULT INSERTION MATRICES | ||||||||
Type | Current | Switch Type | Voltage | Max Power | Matrix Size | Connector | PXI Slots | Part No. |
2 Pin Breakout | 1 A (1.2 A) | Reed Relay | 150 VDC/100 VAC | 20 W | Dual 31 x 4 | 78-pin Male D-type | 4 | 40-592A-011 |
Dual 62 x 4 | 40-592A-012 | |||||||
Dual 93 x 4 | 40-592A-013 | |||||||
Dual 124 x 4 | 40-592A--014 | |||||||
Dual 31 x 4 | 78-pin Male D-type | 8 | 40-592A-111 | |||||
Dual 62 x 4 | 40-592A-112 | |||||||
Dual 93 x 4 | 40-592A-113 | |||||||
Dual 124 x 4 | 40-592A-114 | |||||||
Dual 155 x 4 | 40-592A-115 | |||||||
Dual 186 x 4 | 40-592A-116 | |||||||
Dual 217 x 4 | 40-592A-117 | |||||||
Dual 248 x 4 | 40-592A--118 | |||||||
3 Pin Breakout | 1 A (1.2 A) | Reed Relay | 150 VDC/100 VAC | 20 W | Dual 20 x 4 | 78-pin Male D-type | 4 | 40-592A-001 |
Dual 40 x 4 | 40-592A-002 | |||||||
Dual 60 x 4 | 40-592A-003 | |||||||
Dual 80 x 4 | 40-592A--004 | |||||||
Dual 20 x 4 | 78-pin Male D-type | 8 | 40-592A-101 | |||||
Dual 40 x 4 | 40-592A-102 | |||||||
Dual 60 x 4 | 40-592A-103 | |||||||
Dual 80 x 4 | 40-592A--104 | |||||||
Dual 100 x 4 | 40-592A-105 | |||||||
Dual 120 x 4 | 40-592A-106 | |||||||
Dual 140 x 4 | 40-592A-107 | |||||||
Dual 160 x 4 | 40-592A-108 |
FAULT INSERTION BREAK-OUT MATRIX (3 PIN) | |||||||||
Current | Switch Type | Voltage (Crosspoint) | Max Power (Crosspoint) | Voltage (Breakout) | Max Power (Breakout) | Matrix Size | Connector | PXI
Slots |
Part No. |
10 A
Crosspoint, 8 A Breakout |
EMR | 125 VDC/250 VAC | 300 W/2500 VA | 125 VDC/250 VAC | 240 W/2000 VA | Dual 6 x 2 | 37-pin Male D-type | 8 | 40-595A-001 |
Dual 12 x 2 | 40-595A-002 | ||||||||
Dual 18 x 2 | 40-595A-003 | ||||||||
Dual 24 x 2 | 40-595A-004 | ||||||||
Dual 30 x 2 | 40-595A-005 | ||||||||
Dual 6 x 4 | 40-595A-006 | ||||||||
Dual 12 x 4 | 40-595A-007 | ||||||||
Dual 18 x 4 | 40-595A-008 | ||||||||
Dual 24 x 4 | 40-595A-009 | ||||||||
Dual 30 x 4 | 40-595A-010 |