我们提供用于模拟应变计的仿真模块 —— 用于在机械系统中测量结构部件的拉伸或压缩,还可用于模拟惠斯通电桥压力传感器/变送器。这类仿真要求极其精密的设置分辨率,以及很高的精度和稳定的温度。

这些应变计仿真模块非常适用于在各种工业控制系统中对应变计的测试。这些模块以实惠的价格提供极佳的性能,可以提供6、4或2个通道,方便代替用户自行研发的传感器。这些模块采用跟真实的应变计一样的电阻桥技术,确保在各种条件下仿真的高准确度。

另外,我们还提供配套的 线缆和连接器,并且为我们的所有产品提供 三年质保
其他资讯请查阅我们的 在线知识库 或直接 联系我们

下表可帮助您选择适合您应用的产品型号:

PXI应变计仿真模块 / 压力传感器仿真模块 | Pickering
Untitled Button
Channels
Channel Type
Max R (Ω)
Resolution (Ω)
Accuracy (%)
Min R (Ω)
Price

40-265-202

PXI Strain Gauge Simulator Module 2-Channel, 1KΩ

Simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems

Channels
2
Channel Type
Strain Gauge
Max R (Ω)
1053
Resolution (Ω)
0.01
Accuracy (%)
0.06
Min R (Ω)
947
Product Type
Programmable Resistors
Platform
PXI
¥26,900

40-265-102

PXI Strain Gauge Simulator Module 2-Channel, 3kΩ

Simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems

Channels
2
Channel Type
Strain Gauge
Max R (Ω)
3159
Resolution (Ω)
0.025
Accuracy (%)
0.06
Min R (Ω)
2841
Product Type
Programmable Resistors
Platform
PXI
¥27,650

40-265-012

PXI总线应变传感器仿真模块 2通道 350 Ohm

仿真多种应变传感器的输出,非常适用于测试应变计和各种工业控制系统

Channels
2
Channel Type
Strain Gauge
Max R (Ω)
357
Resolution (Ω)
0.002
Accuracy (%)
0.03
Min R (Ω)
343
Product Type
Programmable Resistors
Platform
PXI
¥27,650

40-265-402

PXI Strain Gauge Simulator Module 2-Channel, 1.5KΩ

Simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems

Channels
2
Channel Type
Strain Gauge
Max R (Ω)
1579.5
Resolution (Ω)
0.0125
Accuracy (%)
0.06
Min R (Ω)
1420/1420.5
Product Type
Programmable Resistors
Platform
PXI
¥27,650

40-265-302

PXI Strain Gauge Simulator Module 2-Channel, 2KΩ

Simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems

Channels
2
Channel Type
Strain Gauge
Max R (Ω)
2106
Resolution (Ω)
0.02
Accuracy (%)
0.06
Min R (Ω)
1894
Product Type
Programmable Resistors
Platform
PXI
¥27,650

40-265-014

PXI Strain Gauge Simulator Module 4-Channel, 350Ω

Simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems

Channels
4
Channel Type
Strain Gauge
Max R (Ω)
357
Resolution (Ω)
0.002
Accuracy (%)
0.03
Min R (Ω)
343
Product Type
Programmable Resistors
Platform
PXI
¥35,400

40-265-204

PXI Strain Gauge Simulator Module 4-Channel, 1kΩ

Simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems

Channels
4
Channel Type
Strain Gauge
Max R (Ω)
1053
Resolution (Ω)
0.01
Accuracy (%)
0.06
Min R (Ω)
947
Product Type
Programmable Resistors
Platform
PXI
¥35,400

40-265-104

PXI Strain Gauge Simulator Module 4-Channel, 3kΩ

Simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems

Channels
4
Channel Type
Strain Gauge
Max R (Ω)
3159
Resolution (Ω)
0.025
Accuracy (%)
0.06
Min R (Ω)
2841
Product Type
Programmable Resistors
Platform
PXI
¥36,350

40-265-404

PXI Strain Gauge Simulator Module 4-Channel, 1.5kΩ

Simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems

Channels
4
Channel Type
Strain Gauge
Max R (Ω)
1579.5
Resolution (Ω)
0.0125
Accuracy (%)
0.06
Min R (Ω)
1420/1420.5
Product Type
Programmable Resistors
Platform
PXI
¥36,350

40-265-304

PXI Strain Gauge Simulator Module 4-Channel, 2kΩ

Simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems

Channels
4
Channel Type
Strain Gauge
Max R (Ω)
2106
Resolution (Ω)
0.02
Accuracy (%)
0.06
Min R (Ω)
1894
Product Type
Programmable Resistors
Platform
PXI
¥36,350

40-265-016

PXI Strain Gauge Simulator Module 6-Channel, 350Ω

Simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems

Channels
6
Channel Type
Strain Gauge
Max R (Ω)
357
Resolution (Ω)
0.002
Accuracy (%)
0.03
Min R (Ω)
343
Product Type
Programmable Resistors
Platform
PXI
¥44,225

40-265-106

PXI Strain Gauge Simulator Module 6-Channel, 3kΩ

Simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems

Channels
6
Channel Type
Strain Gauge
Max R (Ω)
3159
Resolution (Ω)
0.025
Accuracy (%)
0.06
Min R (Ω)
2841
Product Type
Programmable Resistors
Platform
PXI
¥45,550

40-265-206

PXI Strain Gauge Simulator Module 6-Channel, 1kΩ

Simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems

Channels
6
Channel Type
Strain Gauge
Max R (Ω)
1053
Resolution (Ω)
0.01
Accuracy (%)
0.06
Min R (Ω)
947
Product Type
Programmable Resistors
Platform
PXI
¥45,550

40-265-406

PXI Strain Gauge Simulator Module 6-Channel, 1.5kΩ

Simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems

Channels
6
Channel Type
Strain Gauge
Max R (Ω)
1579.5
Resolution (Ω)
0.0125
Accuracy (%)
0.06
Min R (Ω)
1420/1420.5
Product Type
Programmable Resistors
Platform
PXI
¥45,550

40-265-306

PXI Strain Gauge Simulator Module 6-Channel, 2kΩ

Simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems

Channels
6
Channel Type
Strain Gauge
Max R (Ω)
2106
Resolution (Ω)
0.02
Accuracy (%)
0.06
Min R (Ω)
1894
Product Type
Programmable Resistors
Platform
PXI
¥45,550

Filter

Channels

The number of discrete channels in a single topology.

Channel Type

The topology of each channel

Max R (Ω)

Maximum resistance each channel may be programmed to

Resolution (Ω)

Smallest discrete setting step for each resistance channel

Accuracy (%)

The accuracy of programmed resistance

Min R (Ω)

Minimum resistance each channel may be programmed to

Loading