Expanding a Matrix Size

Expanding matrix size is often necessary for various reasons, the most common being that the required size isn’t available in a single device or module. This is especially true in PXI systems, where the modular design imposes limitations on the maximum matrix size that can be achieved.

If you can, choose an integrated solution

While many devices and modules offer expansion options, users should note that this can often be an expensive undertaking unless the system is specifically designed to facilitate easy and cost-effective expansion.

With LXI, the mechanical flexibility enables the implementation of much larger, high-density matrices at a more economical cost. Expanding an LXI device is straightforward and involves simply adding a cable assembly to connect additional devices. For example, the LXI high-density matrix model 60-552 allows users to scale its already impressive 64x64 matrix simply by attaching a 78-pin D-type cable assembly, providing an efficient and seamless path to greater capacity.

For PXI users, a multi-slot BRIC module is an excellent choice for implementing larger matrices, offering a more efficient and scalable solution.

Opting for an integrated matrix solution instead of connecting multiple smaller devices offers numerous benefits:

  • Reduced labor and costs: Eliminates the need for extensive wiring and connector accessories, saving both time and money.
  • Enhanced reliability: A single integrated system minimizes potential points of failure.
  • Streamlined testing: No additional verification is required to ensure the switching system is correctly configured.
  • Simplified programming: The matrix can be programmed as a unified system rather than a collection of disparate parts, speeding up test program development and reducing complexity, with less reliance on advanced tools.
  • Improved performance: Shorter connection paths boost overall matrix efficiency.
  • Easier fault diagnosis: Troubleshooting becomes more straightforward in the event of a system failure.
  • Centralized diagnostics: Tools like BIRST enable fault identification from a single test platform.

By choosing an integrated matrix solution, users can significantly improve efficiency, reliability, and overall system performance.

Understanding the performance issues of expansion

Sometimes, users have no alternative but to expand the switching system by adding additional devices or modules. However, it’s important to understand the challenges that come with expanding a matrix:

Direct Connection Expansion - With this method, users expand the matrix by directly adding a cable to link either the Y-axis, the X-axis, or both. It is the simplest expansion technique to implement and understand. One example can be found in the 60-552 data sheet.

If only X-axis expansion is needed, the Y-bus connections of two devices are linked, creating a single Y-axis while providing two separate sets of X-axes—one in each device. However, this method affects bandwidth (BW). The Y-axis now supports twice as many relays, along with the additional cable length connecting the devices. As a result, the matrix's bandwidth is reduced, but it functions as a single unified matrix.

Certain BRIC matrices, especially those with a wide analog bus, utilize this expansion approach effectively.

60-552 LXI matrix expansion

Expanding a matrix in both the X and Y direction using a direct connection, in this case using
an example of 60-552 which has dedicated connectors for expansion purposes

Loop-Through Connection - In this setup (assuming the X axis is being expanded), the Y axes are still linked, but a relay is introduced to manage the Y signal routing. The signal can either be directed to the device's internal matrix or to a second matrix. This reduces the load on the Y axis since, if the internal matrix is selected, the connection is made directly. If the second matrix is chosen, the signal is routed through an interconnecting cable to the second matrix. This configuration avoids bandwidth degradation but comes with trade-offs: the loop-through relay adds cost and takes up additional space. Additionally, some functionality is lost, as connecting the X of one matrix to the X of another becomes less straightforward. This system is commonly used in RF matrices, which are primarily designed for Y-to-X connections, where preserving bandwidth is a top priority.
Example of a Loop Thru connection on a 2x2 RF PXI matrix (40-837)

Example of a Loop Thru connection on a 2x2 RF matrix (40-837)

  • Isolation Relay. In this setup, the matrices feature isolation relays that disconnect the matrix when a connection is not needed. Although the connecting cable between two traces remains connected, resulting in some bandwidth degradation, the impact is significantly less compared to the Direct Connection method. Matrix functionality is fully preserved. This connection method is commonly used in BRIC systems with 8-way or smaller analog backplanes, as well as in LXI products like the high-density 2A matrix, model 60-554.
Using isolation relays to exapand a matrix, leaving the interconnection bus in place

sing isolation relays to expand a matrix, leaving the interconnection bus in place.
This method is used in both LXI and PXI matrices for intermediate BW's.

Making it Easy to Expand

The simplest matrices to expand are those where the expansion is achieved using a connector separate from the UUT connection (X or Y). This approach allows for easy expansion without disrupting the primary connections of interest to the user. LXI products are generally better suited for this setup compared to PXI products, primarily due to the space constraints imposed by the PXI standard on the front panel. Many LXI products utilize these dedicated connections, enabling the use of standard off-the-shelf cabling accessories, which adds convenience and flexibility.

Summary

With the exception of the Loop Thru Connection method, expanding the size of a matrix can significantly affect its bandwidth (BW). It can also influence other performance factors, such as noise immunity and path resistance. The extent of this degradation depends on how the expansion is implemented—considerations like cable lengths, shielding, and overall setup play a critical role. The more complex the expansion method, the higher the likelihood of unwanted performance issues. This highlights an important takeaway: opting for an integrated matrix of sufficient size, whether in PXI or LXI form factors, is often the smarter and more reliable choice.

How did we do?
0 out of 0 people found this helpful.
Beta

How can I help?

Hi , I'm TESS - your friendly AI agent

Press Enter to submit

TESS is a moderated, AI agent. TESS can make mistakes, please verify important information independently.


Chat history

Log in or create an account to save & continue your chats with TESS.

Log in

or create an account