最高2A的大规模PXI矩阵模块 —— BRIC™

  • 大规模集成矩阵,最多可具有3072个节点
  • 无需用户配置
  • 优化了通道性能,并且可扩展
  • 多种矩阵尺寸可供选择,提供4,6,8,12或16条Y连接
  • 部分产品可选缩减规模的配置
  • 快速的操作时间 < 3ms
  • 占用2,4或8个3U PXI槽位

我们的2A PXI大规模矩阵模块使用高品质的电磁继电器来实现2A的额定切换电流。
BRIC结构 无需用户使用昂贵的外部线缆就可以构建多槽位的大规模PXI矩阵。完全集成的编程接口可将矩阵当作一个整体来进行操作,使得用户编程更为简便,并且降低了用户出错的可能性。

部分模块可被我们的 诊断测试工具,内置继电器自诊断(BIRST)和eBIRST开关系统测试工具 所支持,这些工具使得在LXI、PCI和PXI开关系统中查找继电器故障更为快速简便。 下方的表格有助于您选择适合您应用的产品类型:

下方的表格有助于您选择适合您应用的产品类型:
2A 大规模 PXI 矩阵模块 —— BRIC | Pickering Interfaces
Untitled Button
Switch Type
Max I (A)
Max V DC
Poles
Banks
X Size
Y Size
Price

40-565C-102-192X8

PXI 8-Slot BRIC Matrix, 192x8 2-Pole, 2A (8 sub-cards)

High-density matrix modules constructed using high-quality electro-mechanical relays.

Switch Type
EMR
Max I (A)
2
Max V DC
150
Poles
2
Banks
1
X Size
192
Y Size
8
Product Type
Matrices
Platform
PXI
Function
Matrix
¥206,950

40-573-102-203X8

PXI 8-Slot High Density 2A BRIC Matrix, 203x8 2-Pole (7 Sub-cards)

High-density matrix modules constructed using high-quality EMRs. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Switch Type
EMR
Max I (A)
2
Max V DC
240
Poles
2
Banks
1
X Size
203
Y Size
8
Product Type
Matrices
Platform
PXI
¥209,850

设计并可视化完整测试系统的信号路径

将系统配置、原理图设计、线缆设计和产品选型整合为测试系统开发的统一工作流程。

开始设计

Design and Visualise Test System Signal Paths

Design test system switching and signal routing.

40-596A-105

PXI 8-Slot BRIC Matrix, 2A 1-Pole 290x6, 5 Sub-cards

High-density matrix modules able to switch up to 2 Amps or 300VDC/250VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
290
Y Size
6
Product Type
Matrices
Platform
PXI
¥212,600

40-568A-106

PXI 8-Slot BRIC Matrix, 2A 1-Pole 450x4, 6 Sub-cards

High-density matrix modules able to switch up to 2 A or 300VDC/250VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
450
Y Size
4
Product Type
Matrices
Platform
PXI
¥211,450

40-567A-106

PXI 8-Slot BRIC Matrix, 2A 1-Pole 264x8, 6 Sub-cards

High-density matrix modules able to switch up to 2 A or 100VDC/70VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
100
Poles
1
Banks
1
X Size
264
Y Size
8
Product Type
Matrices
Platform
PXI
¥248,050

40-597A-105

PXI 8 Slot BRIC Matrix, 2A 1-Pole 160x12, 5 Sub-cards

High-density matrix modules able to switch up to 2 A or up to 200 VDC/210VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
200
Poles
1
Banks
1
X Size
160
Y Size
12
Product Type
Matrices
Platform
PXI
¥234,450

40-598A-105

PXI 8 Slot BRIC Matrix, 2A 1-Pole 120x16, 5 Sub-cards

High-density matrix modules able to switch up to 2 Amps or 300 VDC/250 VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
120
Y Size
16
Product Type
Matrices
Platform
PXI
Function
Matrix
¥234,450

40-573-102-232X8

PXI 8-Slot High Density 2A BRIC Matrix, 232x8 2-Pole (8 Sub-cards)

High-density matrix modules constructed using high-quality EMRs. Supported by our Diagnostic Test Tools: BIRST and eBIRST

Switch Type
EMR
Max I (A)
2
Max V DC
240
Poles
2
Banks
1
X Size
232
Y Size
8
Product Type
Matrices
Platform
PXI
¥250,000

40-568A-107

PXI 8-Slot BRIC Matrix, 2A 1-Pole 525x4, 7 Sub-cards

High-density matrix modules able to switch up to 2 A or 300VDC/250VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
525
Y Size
4
Product Type
Matrices
Platform
PXI
¥246,650

40-596A-106

PXI 8-Slot BRIC Matrix, 2A 1-Pole 348x6, 6 Sub-cards

High-density matrix modules able to switch up to 2 Amps or 300VDC/250VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
348
Y Size
6
Product Type
Matrices
Platform
PXI
¥255,225

40-567A-107

PXI 8-Slot BRIC Matrix, 2A 1-Pole 308x8, 7 Sub-cards

High-density matrix modules able to switch up to 2 A or 100VDC/70VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
100
Poles
1
Banks
1
X Size
308
Y Size
8
Product Type
Matrices
Platform
PXI
¥289,425

40-597A-106

PXI 8 Slot BRIC Matrix, 2A 1-Pole 192x12, 6 Sub-cards

High-density matrix modules able to switch up to 2 A or up to 200 VDC/210VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
200
Poles
1
Banks
1
X Size
192
Y Size
12
Product Type
Matrices
Platform
PXI
¥281,450

40-598A-106

PXI 8 Slot BRIC Matrix, 2A 1-Pole 144x16, 6 Sub-cards

High-density matrix modules able to switch up to 2 Amps or 300 VDC/250 VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
144
Y Size
16
Product Type
Matrices
Platform
PXI
Function
Matrix
¥281,450

40-568A-108

PXI 8-Slot BRIC Matrix, 2A 1-Pole 600x4, 8 Sub-cards

High-density matrix modules able to switch up to 2 A or 300VDC/250VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
600
Y Size
4
Product Type
Matrices
Platform
PXI
¥273,850

40-596A-107

PXI 8-Slot BRIC Matrix, 2A 1-Pole 406x6, 7 Sub-cards

High-density matrix modules able to switch up to 2 Amps or 300VDC/250VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
406
Y Size
6
Product Type
Matrices
Platform
PXI
¥297,650

40-567A-108

PXI 8-Slot BRIC Matrix, 2A 1-Pole 352x8, 8 Sub-cards

High-density matrix modules able to switch up to 2 A or 100VDC/70VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
100
Poles
1
Banks
1
X Size
358
Y Size
8
Product Type
Matrices
Platform
PXI
¥330,625

40-597A-107

PXI 8 Slot BRIC Matrix, 2A 1-Pole 224x12, 7 Sub-cards

High-density matrix modules able to switch up to 2 A or up to 200 VDC/210VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
200
Poles
1
Banks
1
X Size
224
Y Size
12
Product Type
Matrices
Platform
PXI
¥328,350

40-598A-107

PXI 8 Slot BRIC Matrix, 2A 1-Pole 168x16, 7 Sub-cards

High-density matrix modules able to switch up to 2 Amps or 300 VDC/250 VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
168
Y Size
16
Product Type
Matrices
Platform
PXI
Function
Matrix
¥328,350

40-596A-108

PXI 8-Slot BRIC Matrix, 2A 1-Pole 464x6, 8 Sub-cards

High-density matrix modules able to switch up to 2 Amps or 300VDC/250VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
464
Y Size
6
Product Type
Matrices
Platform
PXI
¥340,000

40-597A-108

PXI 8 Slot BRIC Matrix, 2A 1-Pole 256x12, 8 Sub-cards

High-density matrix modules able to switch up to 2 A or up to 200 VDC/210VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
200
Poles
1
Banks
1
X Size
256
Y Size
12
Product Type
Matrices
Platform
PXI
¥375,200

40-598A-108

PXI 8 Slot BRIC Matrix, 2A 1-Pole 192x16, 8 Sub-cards

High-density matrix modules able to switch up to 2 Amps or 300 VDC/250 VAC. Supported by our eBIRST Switching System Test Tools

Switch Type
EMR
Max I (A)
2
Max V DC
300
Poles
1
Banks
1
X Size
192
Y Size
16
Product Type
Matrices
Platform
PXI
Function
Matrix
¥375,200

40-568-201

PXI 2 Slot BRIC 75x4 2A 1-pole matrix

Alternative product available, please refer to the 40-568A range.

Switch Type
EMR
Max I (A)
2
Max V DC
200
Poles
1
Banks
1
X Size
75
Y Size
4
Product Type
Matrices
Platform
PXI

40-568-202

PXI 2 Slot BRIC 150x4 2A 1-pole matrix

Alternative product available, please refer to the 40-568A range.

Switch Type
EMR
Max I (A)
2
Max V DC
200
Poles
1
Banks
1
X Size
150
Y Size
4
Product Type
Matrices
Platform
PXI

Filter

Switch Type

EMR - Electro-Mechanical Relay, cost-effective, medium power switching. Reed - reed relays, excellent low-level switching, fast, long life. Solid-State - very fast, indefinite life, high power switching, but high leakage and insertion loss.

Max I (A)

Maximum continuous current each switch can carry.

Max V DC

The maximum voltage that may be applied to each switch.

Poles

The number of common terminals simultaneously switched by a single operation. … more

Banks

The number of independent switch topologies on a single module.

Y Size

The number of matrix rows, used with X Size to specify the size of a cross-point matrix.