Power Distribution MUX Using 40-500

Our PXI solid-state high-density matrix (model 40-500) can be used as a MUX for distributing power supplies to many pins of a test system.

Using low-power relays, such as reed relays or EMRs, to distribute power in a test system where hot switching is required can present significant challenges. Power supplies often feature decoupling capacitors in the load, and the source (i.e., the power supply) typically includes an output capacitor that isn’t constrained by current limiting. Even when a power supply has a current limit, it operates through a feedback system, meaning the limit doesn’t engage instantly during hot switching. These factors can significantly reduce relay lifespan—or even cause them to fail abruptly.

See our article on hot switching relays

Most switching systems are typically designed with PCB tracks rated to match the relays, but this approach can introduce additional challenges. For instance, if a switching system needs to distribute 100mA to 50 test points, the power supply connection must handle 5A. This often necessitates a 5A-rated switching system with larger relays. However, some designs feature PCB tracks with higher current ratings than the relays they use. The 40-500 (and 40-501) series serves as a notable example of this approach.

Using 40-500 as a Power Distribution MUX

Imagine an application that requires distributing a power rail to 64 test points, each capable of drawing up to 100mA. To maximize test system efficiency, the power rail must support hot switching. Consequently, the power supply must deliver up to 5A to meet these demands.

The 40-500 is a 64x4 solid-state matrix designed for reliable and efficient performance. Its solid-state switches excel at hot switching into capacitive loads without suffering from lifetime degradation, making them ideal for applications requiring durability and precision. With rapid switching speeds, the 40-500 is particularly suited for test scenarios where speed is critical. Additionally, it can function effectively as a power distribution multiplexer, as demonstrated in its application.

Diagram of the 40-500 MUX used as a power distributor

Each Y bus on the 40-500 is rated for 3A, making it capable of supporting up to 16 simultaneous connections, each carrying 100mA with ease. By connecting the power source to Y1, Y2, Y3, and Y4, and allocating 16 X connections per Y bus, the required 1.6A per Y is effortlessly handled by the 40-500. Additionally, each crosspoint switch is designed to support a continuous current of 0.5A, comfortably exceeding the 100mA per connection requirement.

The drawing shows Y1 connecting to X1 to X16, Y2 connecting to X17 to X32, Y3 connecting to X33 to X48 and Y4 connecting to X49 to X64. The grey tracks and crosspoints are not used, only the red tracks and crosspoints are used.

How did we do?
0 out of 0 people found this helpful.
Beta

How can I help?

Hi , I'm TESS - your friendly AI agent

Press Enter to submit

TESS is a moderated, AI agent. TESS can make mistakes, please verify important information independently.


Chat history

Log in or create an account to save & continue your chats with TESS.

Log in

or create an account