Pickering Driver Error Codes

Pickering Driver Error Codes - Pilpxi.h

0
NO_ERR
No Error
1
ER_NO_CARD
No Pickering card has the specified number
2
ER_NO_INFO
Card information unobtainable - hardware problem
3
ER_CARD_DISABLED
Card disabled - hardware problem
4
ER_BAD_SUB
Sub-unit value out-of-range for target card
5
ER_BAD_BIT
Bit-number out-of-range for target sub-unit
6
ER_NO_CAL_DATA
Target sub-unit has no calibration data to read/write
7
ER_BAD_ARRAY
Array type, shape or size is incorrect
8
ER_MUX_ILLEGAL
Non-zero write data is illegal for MUX sub-unit
9
ER_EXCESS_CLOSURE
Sub-unit closure limit exceeded
10 
ER_ILLEGAL_MASK
One or more of the specified channels cannot be masked
11
ER_OUTPUT_MASKED
Cannot activate an output that is masked
12
ER_BAD_LOCATION
Cannot open a Pickering card at the specified location
13
ER_READ_FAIL
Failed read from hardware
14
ER_WRITE_FAIL
Failed write to hardware
15
ER_DRIVER_OP
Hardware driver failure
16
ER_DRIVER_VERSION
Incompatible hardware driver version
17
ER_SUB_TYPE
Function call incompatible with sub-unit type or capabilities
18
ER_BAD_ROW
Matrix row value out-of-range
19
ER_BAD_COLUMN
Matrix column value out-of-range
20
ER_BAD_ATTEN
Attenuation value out-of-range
21
ER_BAD_VOLTAGE
Voltage value out-of-range
22
ER_BAD_CAL_INDEX
Calibration reference out-of-range
23
ER_BAD_SEGMENT
Segment number out of range
24
ER_BAD_FUNC_CODE
Function code value out of range
25
ER_BAD_SUBSWITCH
Subswitch value out of range
26
ER_BAD_ACTION
Action code out of range
27
ER_STATE_CORRUPT
Cannot execute due to corrupt sub-unit state
28
ER_BAD_ATTR_CODE
Unrecognised attribute code
29
ER_EEPROM_WRITE_TMO
Timeout writing to EEPROM
30
ER_ILLEGAL_OP
Operation is illegal in the sub-unit's current state
31
ER_BAD_POT
Unrecognised pot number requested
32
ER_MATRIXR_ILLEGAL
Invalid write pattern for MATRIXR/MATRIXS sub-unit
33
ER_MISSING_CHANNEL
Attempted operation on non-existent channel
34
ER_CARD_INACCESSIBLE
Card cannot be accessed (failed/removed/unpowered)
35
ER_BAD_FP_FORMAT
Unsupported internal floating-point format (internal error)
36
ER_UNCALIBRATED
Sub-unit is not calibrated
37
ER_BAD_RESISTANCE
Unobtainable resistance value
38
ER_BAD_STORE
Invalid calibration store number
39
ER_BAD_MODE
Invalid mode value
40
ER_SETTINGS_CONFLICT
Conflicting device settings
41
ER_CARD_TYPE
Function call incompatible with card type or capabilities
42
ER_BAD_POLE
Switch pole value out of range
43
ER_MISSING_CAPABILITY
Attempted to activate a non-existent capability
44
ER_MISSING_HARDWARE
Action requires hardware that is not present
45
ER_HARDWARE_FAULT
Faulty hardware
46
ER_EXECUTION_FAIL
Failed to execute (e.g. blocked by a hardware condition)
47
ER_BAD_CURRENT
Current value out of range
48
ER_BAD_RANGE
Invalid range value
49
ER_ATTR_UNSUPPORTED
Attribute not supported
50
ER_BAD_REGISTER
Register number out of range
51
ER_MATRIXP_ILLEGAL
Invalid channel closure or write pattern for MATRIXP sub-unit
52
ER_BUFFER_UNDERSIZE
Data buffer too small
53
ER_ACCESS_MODE
Inconsistent shared access mode
54
ER_POOR_RESISTANCE
Resistance outside limits
55
ER_BAD_ATTR_VALUE
Bad attribute value
56
ER_INVALID_POINTER
Invalid pointer
57
ER_ATTR_READ_ONLY
Attribute is read only
58
ER_ATTR_DISABLED
Attribute is disabled
59
ER_PSU_MAIN_OUTPUT_DISABLED
Main output is disabled, cannot enable the channel
60
ER_OUT_OF_MEMORY_HEAP
Unable to allocate memory on Heap
61
ER_INVALID_PROCESSID
Invalid ProcessID
62
ER_SHARED_MEMORY
Shared memory error
63
ER_CARD_OPENED_OTHER_PROCESS
Card is opened by a process in exclusive mode
64
ER_DIO_PORT_DISABLED
DIO card PORT is disabled due to Over-Current Scenario
65 ER_DIO_INVALID_FILE DIO pattern File is invalid
66 ER_DIO_DYNAMIC_ACTIVE DIO dynamic operation active, action not permissible
67 ER_DIO_FILE_ENTRY_ERR DIO file entry error, check file entries
69 ER_HW_INT_NOT_SUPPORTED Hardware Interlock feature not supported for the card
70 ER_HW_INT_ERROR Hardware Interlock is not detected on the card, cannot use the function
71 ER_SMS_CH_ENABLE_ERR Channel is disabled, so Set-Measure-Set cannot be used
72 ER_MEAS_CURRENT Measured current out of range
73 ER_BAD_TEMPERATURE Temperature value out of range
74 ER_CMP_ENGINE_ON Capture engine running - operation unobtainable
75 ER_WRITEPATTERN_ILLEGAL Invalid write pattern
76 ER_DDS_ON DDS engine running - operation unobtainable
77 ER_WAVEFORM_UNSUPPORTED Waveform unsupported
78 ER_BAD_WAVEFORM Operation unavailable for selected waveform
79 ER_FILE_UNAVAILABLE File unavailable or doesn't exist
80 ER_BAD_FILE File content invalid
81 ER_BAD_AMPLITUDE Amplitude value out of range
82 ER_BAD_DC_OFFSET DC offset value out of range
83 ER_BAD_FREQUENCY Frequency value out of range
84 ER_BAD_PHASE Phase value out of range
85 ER_BAD_DUTY_CYCLE Duty cycle value out of range
86 ER_BAD_PULSE_WIDTH Pulse width value out of range
87 ER_INVALID_COMP_FLAG Invalid flag for setting compatibility logic

Card status bits for PIL_Status(), PIL_SubStatus(), PIPLX SubStatus(), and PIPLX SubStatus() results

Note: Two status codes may be combined together
0x10000000 + 0x02000000 = 0x12000000 (Disabled+HW_Fault) [eg Data loop 2 faulty]

0x80000000UL 
STAT_NO_CARD
No card with specified number
0x40000000UL
STAT_WRONG_DRIVER
Card requires later driver version
0x20000000U
STAT_EEPROM_ERR
Error interpreting card EEPROM data
0x10000000UL
STAT_DISABLED
Card is disabled
0x08000000UL
STAT_NO_SUB
Card has no sub-unit with specified number
0x04000000UL
STAT_BUSY
Busy (card or sub-unit)
0x02000000UL
STAT_HW_FAULT
Hardware fault (eg. defective serial loop)
0x01000000UL
STAT_PARITY_ERROR
9050 Parity Error
0x00800000UL
STAT_PSU_INHIBITED
PSU sub-unit - supply is disabled (by software)
0x00400000UL
STAT_PSU_SHUTDOWN
PSU sub-unit - supply is shutdown (due to overload)
0x00200000UL
STAT_PSU_CURRENT_LIMIT
PSU sub-unit - supply is operating in current-limited mode
0x00100000UL
STAT_CORRUPTED
Sub-unit logical state is corrupted
0x00080000UL
STAT_CARD_INACCESSIBLE
Card cannot be accessed (failed/removed/unpowered)
0x00040000UL
STAT_UNCALIBRATED
Calibration data is faulty (card or sub-unit)
0x00020000UL
STAT_CALIBRATION_DUE
Calibration is due (card or sub-unit)
0x00010000UL
STAT_BIRST_ENABLED
BIRST is active (card or sub-unit)
0x00008000UL 
STAT LID CHECKSUM FAIL
Checksm Verification for Legacy-ID feature failed
0x00000000UL
STAT_OK
OK

VISA ERROR CODES - Pipx40.h

You may receive an error code like -1074001918, this is a decimal number so needs to be converted to Hexidecimal before lookup below.

0xbffc0800
pipx40_ERROR_BAD_SESSION
Not a valid pipx40 session
0xbffc0801
pipx40_ERROR_NO_INFO
Card information unobtainable - hardware problem
0xbffc0802
pipx40_ERROR_CARD_DISABLED
Card disabled - hardware problem
0xbffc0803
pipx40_ERROR_BAD_SUB
Card has no sub-unit with specified number
0xbffc0804
pipx40_ERROR_BAD_CHANNEL
Sub-unit has no channel with specified number
0xbffc0805
pipx40_ERROR_NO_CAL_DATA
Sub-unit has no calibration data to read/write
0xbffc0806
pipx40_ERROR_BAD_ARRAY
Array type, hape or size is incorrect
0xbffc0807
pipx40_ERROR_MUX_ILLEGAL
Non-zero write data value is illegal for MUX sub-unit
0xbffc0808
pipx40_ERROR_EXCESS_CLOSURE
Sub-unit closure limit exceeded
0xbffc0809
pipx40_ERROR_ILLEGAL_MASK
One or more of the specified channels cannot be masked
0xbffc080A
pipx40_ERROR_OUTPUT_MASKED
Cannot activate an output that is masked
0xbffc080B
pipx40_ERROR_FAILED_INIT
Cannot open a Pickering card with this resource name
0xbffc080C
pipx40_ERROR_READ_FAIL
Failed read from hardware
0xbffc080D
pipx40_ERROR_WRITE_FAIL
Failed write to hardware
0xbffc080E
pipx40_ERROR_VISA_OP
VISA operation failure
0xbffc080F
pipx40_ERROR_VISA_VERSION
Incompatible VISA version
0xbffc0810
pipx40_ERROR_SUB_TYPE
Function incompatible with sub-unit type or capabilities
0xbffc0811
pipx40_ERROR_BAD_ROW
Matrix row value out-of-range
0xbffc0812
pipx40_ERROR_BAD_COLUMN
Matrix column value out-of-range
0xbffc0813
pipx40_ERROR_BAD_ATTEN
Attenuation value out-of-range
0xbffc0814
pipx40_ERROR_BAD_VOLTAGE
Voltage value out-of-range
0xbffc0815
pipx40_ERROR_BAD_CAL_INDEX
Calibration reference out-of-range
0xbffc0816
pipx40_ERROR_BAD_SEGMENT
Segment number out of range
0xbffc0817
pipx40_ERROR_BAD_FUNC_CODE
Function code value out of range
0xbffc0818
pipx40_ERROR_BAD_SUBSWITCH
Subswitch value out of range
0xbffc0819
pipx40_ERROR_BAD_ACTION
Action code out of range
0xbffc081A
pipx40_ERROR_STATE_CORRUPT
Cannot execute due to corrupt sub-unit state
0xbffc081B
pipx40_ERROR_BAD_ATTR_CODE
Unrecognised attribute code
0xbffc081C
pipx40_ERROR_EEPROM_WRITE_TMO
Timeout writing to EEPROM
0xbffc081D
pipx40_ERROR_ILLEGAL_OP
Operation is illegal in the sub-unit's current state
0xbffc081E
pipx40_ERROR_BAD_POT
Unrecognised pot number requested
0xbffc081F
pipx40_ERROR_MATRIXR_ILLEGAL
Invalid write pattern for MATRIXR/MATRIXS sub-unit
0xbffc0820
pipx40_ERROR_MISSING_CHANNEL
Attempted operation on non-existent channel
0xbffc0821
pipx40_ERROR_CARD_INACCESSIBLE
Card cannot be accessed failed/removed/unpowered
0xbffc0822
pipx40_ERROR_BAD_FP_FORMAT
Unsupported internal floating-point format (internal error)
0xbffc0823
pipx40_ERROR_UNCALIBRATED
Sub-unit is not calibrated
0xbffc0824
pipx40_ERROR_BAD_RESISTANCE
Unobtainable resistance value
0xbffc0825
pipx40_ERROR_BAD_STORE
Invalid calibration store number
0xbffc0826
pipx40_ERROR_BAD_MODE
Invalid mode value
0xbffc0827
pipx40_ERROR_SETTINGS_CONFLICT
Conflicting device settings
0xbffc0828
pipx40_ERROR_CARD_TYPE
Function call incompatible with card type or capabilities
0xbffc0829
pipx40_ERROR_BAD_POLE
Switch pole value out of range
0xbffc082A
pipx40_ERROR_MISSING_CAPABILITY
Attempted to activate a non-existent capability
0xbffc082B
pipx40_ERROR_MISSING_HARDWARE
Action requires hardware that is not present
0xbffc08C
pipx40_ERROR_HARDWARE_FAULT
Faulty hardware
0xbffc082D
pipx40_ERROR_EXECUTION_FAIL
Failed to execute (e.g. blocked by a hardware condition)
0xbffc082E
pipx40_ERROR_BAD_CURRENT
Current value out of range
0xbffc082F
pipx40_ERROR_BAD_RANGE
Invalid range value
0xbffc0830
pipx40_ERROR_ATTR_UNSUPPORTED
Attribute not supported
0xbffc0831
pipx40_ERROR_BAD_REGISTER
Register number out of range
0xbffc0832
pipx40_ERROR_MATRIXP_ILLEGAL
Invalid channel closure or write pattern for MATRIXP sub-unit
0xbffc0833
pipx40_ERROR_BUFFER_UNDERSIZE
Data buffer too small
0xbffc0834
pipx40_ERROR_ACCESS_MODE
Inconsistent shared access mode
0xbffc0835
pipx40_ERROR_POOR_RESISTANCE
Resistance outside limits
0xbffc0836
pipx40_ERROR_BAD_ATTR_VALUE
Bad attribute value
0xbffc0837
pipx40_ERROR_INVALID_POINTER
Invalid pointer
0xbffc0838
pipx40_ERROR_ATTR_READ_ONLY
Attribute is read only
0xbffc0839
pipx40_ERROR_ATTR_DISABLED
Attribute is disabled
0xbffc083A
pipx40_ERROR_PSU_MAIN_DISABLED
Main output is disabled, cannot enable the channel
0xbffc083B
pipx40_ERROR_OUT_OF_MEMORY_HEAP
Unable to allocate memory on Heap
0xbffc083C
pipx40_ERROR_INVALID_PROCESSID
Invalid ProcessID
0xbffc083D
pipx40_ERROR_SHARED_MEMORY
Shared memory error
0xbffc083E
pipx40_ERROR_CARD_OPENED_OTHER_PROCESS
Card is opened by a process in exclusive mode
0xbffc083F
pipx40_ERROR_DIO_PORT_DISABLED
DIO card PORT is disabled due to Over-Current Scenario
0xbffc0840 pipx40_ERROR_DIO_INVALID_FILE DIO pattern file is invalid
0xbffc0841 pipx40_ERROR_DIO_DYNAMIC_ACTIVE DIO Dynamic operation is active, action not permissible
0xbffc0842 pipx40_ERROR_DIO_FILE_ENTRY_ERR DIO File Entry has error, check the file entries
0xbffc0844 pipx40_ERROR_HW_INT_NOT_SUPPORTED Hardware Interlock feature not supported for the card
0xbffc0845 pipx40_ERROR_HW_INT_ERROR Hardware Interlock is not detected on the card, cannot use the function
0xbffc0846 pipx40_ERROR_SMS_CH_ENABLE_ERR Channel is disabled, so Set-Measure-Set cannot be used
0xbffc0847 pipx40_ERROR_MEAS_CURRENT Measured Current out of range
0xbffc0848 pipx40_ERROR_BAD_TEMPERATURE Temperature value out of range
0xbffc0849 pipx40_ERROR_CMP_ENGINE_ON Capture Engine running - operation unobtainable
0xbffc084A pipx40_ERROR_DDS_ON DDS Engine running - operation unobtainable
0xbffc084B pipx40_ERROR_WAVEFORM_UNSUPPORTED Waveform unsupported
0xbffc084C pipx40_ERROR_BAD_WAVEFORM Operation unavailable for selected waveform
0xbffc084D pipx40_ERROR_FILE_UNAVAILABLE File unavailable or does not exist
0xbffc084E pipx40_ERROR_FILE File content invalid
0xbffc084F pipx40_ERROR_AMPLITUDE Amplitude value out of range
0xbffc0850 pipx40_ERROR_WRITEPATTERN_ILLEGAL Invalid write pattern
0xbffc0851 pipx40_ERROR_DC_OFFSET DC Offset value out of range
0xbffc0852 pipx40_ERROR_FREQUENCY Frequency value out of range
0xbffc0853 pipx40_ERROR_PHASE Phase value out of range
0xbffc0854 pipx40_ERROR_DUTY_CYCLE Duty Cycle value out of range
0xbffc0855 pipx40_ERROR_PULSE_WIDTH Pulse Width value out of range
0xbffc0856 pipx40_ERROR_INVALID_COMP_FLAG Invalid flag for setting compatibility logic
0xbffc0fff pipx40_ERROR_UNKNOWN Unknown error code

Card status bits for pipx40_getCardStatus and pipx40_getSubStatus results

Note: Two status codes may be combined together
0x10000000 + 0x02000000 = 0x12000000 (Disabled+HW_Fault) [eg Data loop 2 faulty]

0x80000000UL 
pipx40_STAT_NO_CARD
No Pickering card open on the session
0x40000000UL
pipx40_STAT_WRONG_DRIVER
Card requires later driver version
0x20000000UL
pipx40_STAT_EEPROM_ERR
Error interpreting card EEPROM data
0x10000000UL
pipx40_STAT_DISABLED
Card is disabled
0x08000000UL
pipx40_STAT_NO_SUB
Card has no sub-unit with specified number
0x04000000UL
pipx40_STAT_BUSY
Busy (card or sub-unit)
0x02000000UL
pipx40_STAT_HW_FAULT
Hardware fault (eg. defective serial loop)
0x01000000UL
pipx40_STAT_PARITY_ERROR
PCIbus parity error
0x00800000U
pipx40_STAT_PSU_INHIBITED
PSU sub-unit - supply is disabled (by software)
0x00400000UL
pipx40_STAT_PSU_SHUTDOWN
PSU sub-unit - supply is shutdown (due to overload)
0x00200000UL
pipx40_STAT_PSU_CURRENT_LIMIT
PSU sub-unit - supply is operating in current-limited mode
0x00100000UL
pipx40_STAT_CORRUPTED
Sub-unit logical state is corrupted
0x00080000UL
pipx40_STAT_CARD_INACCESSIBLE
Card cannot be accessed (failed/removed/unpowered)
0x00040000UL
pipx40_STAT_UNCALIBRATED
Calibration data is faulty (card or sub-unit)
0x00020000UL
pipx40_STAT_CALIBRATION_DUE
Calibration is due (card or sub-unit)
0x00010000UL
pipx40_STAT_BIRST_ENABLED
BIRST is active (card or sub-unit
0x00008000UL
pipx40_STAT_LID_CHECKSUM_FAIL
Checksum Verification for Legacy-ID feature failed
0x00000000UL
pipx40_STAT_OK

ClientBridge Driver Error Codes

PIPLX

0
NO_ERR
No error
1
ER_NO_CARD
No Pickering card has the specified number
2
ER_NO_INFO
Card information unobtainable - hardware problem
3
ER_CARD_DISABLED
Specified card is disabled
4
ER_BAD_SUB
Sub-unit value out of range for target card
5
ER_BAD_BIT
Bit number out of range for target sub-unit
6
ER_NO_CAL_DATA
Target sub-unit has no calibration data to read/write
7
ER_BAD_ARRAY
"SafeArray type, shape or size in incorrect"
8
ER_MUX_ILLEGAL
Non zero write data value is illegal for MUX sub-unit
9
ER_EXCESS_CLOSURE
Execution would cause closure limit to be exceeded
10
ER_ILLEGAL_MASK
One or more of the specified channels can not be masked
11
ER_OUTPUT_MASKED
Can not activate an output that is masked
12
ER_BAD_LOCATION
Can not open a Pickering card at the specified location
13
ER_READ_FAIL
Failed read from hardware
14
ER_WRITE_FAIL
Failed write to hardware
15
ER_DRIVER_OP
Hardware driver failure
16
ER_DRIVER_VERSION
Incompatible hardware driver version
17
ER_SUB_TYPE
Function call incompatible with sub-unit type or capabilities
18
ER_BAD_ROW
Matrix row value out of range
19
ER_BAD_COLUMN
Matrix column value out of range
20
ER_BAD_ATTEN
Attenuation value out of range
21
ER_BAD_VOLTAGE
Voltage value out of range
22
ER_BAD_CAL_INDEX
Calibration index value out of range
23
ER_BAD_SEGMENT
Segment number out of range
24
ER_BAD_FUNC_CODE
Function code value out of range
25
ER_BAD_SUBSWITCH
Subswitch value out of range
26
ER_BAD_ACTION
Action code out of range
27
ER_STATE_CORRUPT
Cannot execute due to corrupt sub-unit state
28
ER_BAD_ATTR_CODE
Unrecognized attribute code
29
ER_EEPROM_WRITE_TMO
Timeout writing to EEPROM
30
ER_ILLEGAL_OP
Operation is illegal in the sub-unit's current state
31
ER_BAD_POT
Unrecognized pot number requested
32
ER_MATRIXR_ILLEGAL
Invalid write pattern for MATRIX/MATS sub-unit
33
ER_MISSING_CHANNEL
Attempted operation on non-existent channel
34
ER_CARD_INACCESSIBLE
Card can not be accessed (failed/removed/unpowered)
35
ER_BAD_FP_FORMAT
Unsupported internal floating-point format (internal error)
36
ER_UNCALIBRATED
Sub-unit is not calibrated
37
ER_BAD_RESISTANCE
Unobtainable resistance value
38
ER_BAD_STORE
Invalid calibration store number
39
ER_BAD_MODE
Invalid mode value
40
ER_SETTINGS_CONFLICT
Conflicting device settings
41
ER_CARD_TYPE
Function call incompatible with card type or capabilities
42
ER_BAD_POLE
Switch pole value out of range
43
ER_MISSING_CAPABILITY
Attempt to activate a non-existent capability
44
ER_MISSING_HARDWARE
Action requires hardware that is not present
45
ER_HARDWARE_FAULT
Faulty hardware
46
ER_EXECUTION_FAIL
Failed to execute (e.g. blocked by a hardware condition)
47
ER_BAD_CURRENT
Current value out of range
48
ER_BAD_RANGE
Invalid range value
49
ER_ATTR_UNSUPPORTED
Attribute not supported
50
ER_BAD_REGISTER
Register number out of range
51
ER_MATRIXP_ILLEGAL
Invalid channel closure or write pattern for MATRIXP sub-unit
52
ER_BUFFER_UNDERSIZE
Data buffer too small
53
ER_ACCESS_MODE
Inconsistent shared access mode
54
ER_POOR_RESISTANCE
Unobtainable resistance value
55
ER_BAD_ATTR_VALUE
Unrecognised attribute value
56
ER_INVALID_POINTER
Invalid Pointer
57
ER_ATTR_READ_ONLY
Attribute is read-only
58
ER_ATTR_DISABLED
Attribute is disabled
59
ER_PSU_MAIN_OUTPUT_DISABLED
Main output is disabled, cannot enable the channel
60 ER_OUT_OF_MEMORY_HEAP Unable to allocate memory on Heap
61 ER_INVALID_PROCESSID Invalid ProcessID
62 ER_SHARED_MEMORY Shared memory error
63 ER_CARD_OPENED_OTHER_PROCESS Card is opened by a process in exclusive mode
64 ER_DIO_PORT_DISABLED DIO card PORT is disabled due to Over-Current Scenario
65 ER_DIO_INVALID_FILE DIO pattern File is invalid
66 ER_DIO_DYNAMIC_ACTIVE DIO dynamic operation active, action not permissible
67 ER_DIO_FILE_ENTRY_ERR DIO file entry error, check file entries
69 ER_HW_INT_NOT_SUPPORTED Hardware Interlock feature not supported for the card
70 ER_HW_INT_ERROR Hardware Interlock is not detected on the card, cannot use the function
71 ER_SMS_CH_ENABLE_ERR Channel is disabled, so Set/Measure/Set cannot be used
72 ER_MEAS_CURRENT Measured current out of range
73 ER_BAD_TEMPERATURE Temperature value out of range
74 ER_CMP_ENGINE_ON Capture engine running - operation unobtainable
75 ER_WRITEPATTERN_ILLEGAL Invalid write pattern
87 ER_INVALID_COMP_FLAG Invalid flag for setting compatibility logic
8194
ER_PIPLX_FUNC_NOT_LOADED
Function not loaded from library
8195
ER_PIPLX_NOT_CONNECTED
You are not connected to remote host
8196
ER_PIPLX_FUNC_NOT_LOCAL
Function not supported on localhost
8199
ER_PIPLX_RESMAN_NOT_AVAILABLE
Pickering Resource Manager is not available
8200
ER_PIPLX_INVALID_RSRC
Invalid resource string



PICMLX



4098
ER_PICMLX_CLI_INVALID_SESSION
Client: Invalid session ID
4099
ER_PICMLX_CLI_HOST_UNAVAILABLE
Client: Destination host is unavailable
4109
ER_PICMLX_CLI_CONNECT
Client: Can't connect to device
4110
ER_PICMLX_CLI_CONNECT REFUSED
Client: Connection refused
4111
ER_PICMLX_CLI_NAME NOT KNOWN
Client: Name not known
4112
ER_PICMLX_CLI_RECV_FAILED
Client: Can't receive data
4113
ER_PICMLX_CLI_RECV_DATA
Client: Received corrputed data
4114
ER_PICMLX_CLI_SEND_FAILED
Client: Can't send data
4115
ER_PICMLX_CLI_FUNC_NOT_LOCAL
Client: Function is not supported on local system
4116
ER_PICMLX_CLI_NOT_CONNECTED
Client: Session isn't connected to the device
4117
ER_PICMLX_SRV_RPC_DATA
Server: RPC data corrupt
4118
ER PICMLX CLI DATA NOT ACCEPT Client: Invalid parameter value
4119
ER_PICMLX_SRV_INVALID_FID
Server: Invalid function ID
4120
ER_PICMLX_SRV_RPC_DATA
Server: RPC data are corrupted
4121
ER_PICMLX_SRV_INVALID_CARDID
Server: Invalid card ID
4122
ER_PICMLX_SRV_INVALID_ADDRESS
Server: Address of card is invalid
4123
ER_PICMLX_SRV_OPEN_CARD
Server: The card is used
4124
ER_PICMLX_SRV_ACCESS_DENIED
Server: You haven't any rights to the card(s)
4125
ER_PICMLX_SRV_NOT_SUPPORTED
Server: Function is not supported by this LXI device
4126
ER_PICMLX_SRV_DEVICE_INFO
Server: Information about LXI device is not obtainable
4127
ER_PICMLX_SRV_OUT_OF_RESOURCES
Server: Out of resources (probably memory)
4128
ER_PICMLX_SRV_DATA_LENGTH
Server: Required length of data is too long
4129
ER_PICMLX_SRV_CARD_TYPE
Server: LXI device has no card of this type
4130
ER_PICMLX_SRV_FUNC_NOT_IMPL
Server: Function is not implemented or it is reserved
4131
ER_PICMLX_SRV_CARD_USED_BYCLI
Server: The card is already used by the client
4132
ER_PICMLX_SRV_UNDEFINED
Server: Undefined error
4133
ER_PICMLX_SRV_WAIT_TIMEOUT
Server: Wait timeout expired
4134
ER_PICMLX_SRV_DEVICE_LOCKED
Server: Device is locked - another client has exclusive access
4135
ER_PICMLX_CLI_BEGINTRANS
Client: Transmission wasn't initiated. First call PICMLX_BeginTransmission!
4136
ER_PICMLX_CLI_ENDTRANS
Client: Previous transmission wasn't ended. Call PICMLX_EndTransmission !
4137
ER_PICMLX_CLI_INVALID_INDEX
Client: Invalid list item index
4138
ER_PICMLX_CLI_DIRECTECHO_FAILED
Client: Direct discovery function failed
4139
ER_PICMLX_CLI_BROADCASTECHO_FAILED
Client: Broadcast discovery function failed
4140
ER_PICMLX_SRV_INVALID_SESSION
Server: Invalid session
4141
ER_PICMLX_SRV_INVALID_TOKEN
Server: Invalid token
4142
ER_PICMLX_SRV_INVALID_EC
Server: Invalid error code
4143
ER_PICMLX_SRV_FATAL_01
Server: Fatal error – 1
4144
ER_PICMLX_CLI_TIMEOUT_FAIL
Client: Can not set recv/send socket timeout
4145
ER_PICMLX_CLI_RECV_TIMEDOUT
Client: Can't receive data. Connection timed out
4146
ER_PICMLX_CLI_RECV_RSRC_TEMP_UNAVAILABLE
Client: Can't receive data. Resource temporarily unavailable
4147
ER_PICMLX_SRV_DATACOPY
Server: Error while copying output data to response buffer
4148
ER_PICMLX_SRV_CREATE_DIRECTORY_FAILED
Server: Create directory failed
4149
ER_PICMLX_SRV_DELETE_DIRECTORY_FAILED
Server: Delete directory failed
4150
ER_PICMLX_SRV_DELETE_FILE_FAILED
Server: Delete file failed
4151
ER_PICMLX_SRV_DIRECTORY_NOT_EXISTS
Server: Directory doesn't exist
4152
ER_PICMLX_SRV_FILE_NOT_EXISTS
Server: File doesn't exist
4153
ER_PICMLX_SRV_FILE_OPEN_FAILED
Server: File open failed
4154
ER_PICMLX_SRV_FILE_READ_FAILED
Server: File read failed
4155
ER_PICMLX_SRV_NO_FILE_TRANSFER
Server: No file transfer
4156
ER_PICMLX_SRV_FILE_WRITE_FAILED
Server: File write failed
4157
ER_PICMLX_SRV_SET_ATTRIBUTES_FAILED
Server: Set directory/file attributes failed
4158
ER_PICMLX_CLI_FILE_OPEN_FAILED
Client: Open file failed
4160 ER_PICMLX_CLI_OUT_OF_RESOURCES Client: Out of resources (probably memory)
4161 ER_PICMLX_VXI_NOACCESS VXI-11: Device not accessible
4162 ER_PICMLX_VXI_PARAMERR VXI-11: Parameter error
4163 ER_PICMLX_SRV_PROTECTIONRESET_PERFORMED Protection Reset was performed



PIFGLX

4353 ER_PIFGLX_NULLPOINTER nullpointer exception
4354 ER_PIFGLX_FUNC_NOT_LOADED function not loaded
4428 ER_PIFGLX_DDS_ON DDS Engine running - operation unobtainable
4429 ER_PIFGLX_WAVEFORM_UNSUPPORTED Waveform unsupported
4430 ER_PIFGLX_BAD_WAVEFORM Operation unavailable for selected waveform
4431 ER_PIFGLX_FILE_UNAVAILABLE File unavailable or does not exist
4432 ER_PIFGLX_BAD_FILE File content invalid
4433 ER_PIFGLX_BAD_AMPLITUDE Amplitude value out of range
4434 ER_PIFGLX_BAD_DC_OFFSET DC Offset value out of range
4435 ER_PIFGLX_BAD_FREQUENCY Frequency value out of range
4436 ER_PIFGLX_BAD_PHASE Phase value out of range
4437 ER_PIFGLX_BAD_DUTY_CYCLE Duty Cycle value out of range
4438 ER_PIFGLX_BAD_PULSE_WIDTH Pulse Width value out of range


PIPSLX



12289
ER_PIPSLX_INVALID_SESSION
No longer used - now ER_PICMLX_INVALID_SESSION
12290
ER_PIPSLX_FUNC_NOT_LOCAL
Function not supported on local host
12291
ER_PIPSLX_NOT_CONNECTED
Not connected to remote host
12292
ER_PIPSLX_NOT_INIT
Library not initialized
12293
ER_PIPSLX_SWITCH_FAULT
Switch fault
12294
ER_PIPSLX_BAD_FORMAT_DATA
Data or command format bad
12295
ER_PIPSLX_UNKNOWN_CMD
Unknown command
12296
ER_PIPSLX_BUSY
Device busy
12297
ER_PIPSLX_SEQUPINPROGRESS
Up sequence in progress
12298
ER_PIPSLX_SEQDOWNINPROGRESS
Down sequence in progress
12299
ER_PIPSLX_CHANTESTINPROGRESS
Channel test running
12300
ER_PIPSLX_EMERGENCYSTOP
Emergency stop button engaged
12301
ER_PIPSLX_PARAM_SIZE
Parameter is NULL or invalid size 
How did we do?
0 out of 0 people found this helpful.
Beta

How can I help?

Hi , I'm TESS - your friendly AI agent

Press Enter to submit

TESS is a moderated, AI agent. TESS can make mistakes, please verify important information independently.


Chat history

Log in or create an account to save & continue your chats with TESS.

Log in

or create an account