PXI Low-leakage Switched Guard Switching Solutions

PXI low-leakage switched-guard switching modules route very low-current signals for semiconductor parametric test applications, such as wafer acceptance testing (WAT). Designed for use in a driven-guard test configuration, these modules achieve isolation resistances up to 10¹³ Ω, delivering the accurate, repeatable measurements that high-precision semiconductor testing demands.

Available in both PXI and PXIe formats, the range includes switched guard matrices, multiplexers, and general-purpose relay modules. Each PXI module occupies a single chassis slot and uses specialized Pickering switched-guard reed relays and high-density coaxial connectors to support low-leakage, driven-guard measurements. Loop-thru functionality lets you expand matrix size by interconnecting adjacent modules in a chassis via short standard cables, so your test system can scale as requirements grow.

What Is a Switched Guard Switching Module?

A switched guard switching module carries a guard signal alongside the measurement signal to minimize leakage current. The guard is driven to the same potential as the measurement conductor, thereby suppressing the small leakage currents that otherwise flow across the insulation and connectors.

In practice, this technique is essential when measuring femtoamp- and picoamp-level currents. During wafer acceptance testing (WAT), parametric measurements on semiconductor devices can be corrupted by even tiny leakage paths. By switching the guard along with the signal, these modules preserve isolation resistance up to 10¹³Ω throughout the switching path, so the measurement instrument sees the device under test rather than the surrounding wiring.

Switched guard modules are essential when a standard switch cannot maintain the isolation needed for accurate low-current measurements, particularly in semiconductor parametric and WAT applications.

How Does Switched Guard Technology Work? 

Switched-guard technology maintains the guard conductor at the same voltage as the signal conductor across every switch and connector along the path. Because there's no voltage difference between the signal and its surrounding guard, leakage current across the insulation is effectively eliminated.

The result is that isolation resistance remains high, up to 10¹³Ω, even as signals pass through relays and matrix crosspoints. This makes the modules well suited to driven-guard measurements where signal integrity determines the quality of your parametric test data.

Product Families in This Range

Each product family below addresses a specific switching topology. Use the summaries to match a module to your test architecture.

Switched Guard Matrices 

  • Purpose: Connect multiple instruments to multiple test points through a crosspoint matrix, with switched guard on every path for maximum isolation.
  • Application: Semiconductor parametric test and WAT, where several sources or measurement instruments share a common set of device pins.
  • Technical range: 8x4 and 16x4 configurations, up to 0.5 A, up to 150 V DC, MMCX connectors, custom high-quality Pickering Ruthenium switched-guard reed relays. Available in PXI/PXIe. Scalable in X direction using Loop-Thru connectivity. 
  • Example modules: 40–590–102 (8x4) and 40–590–101 (16x4). 

Switched Guard Multiplexers 

  • Purpose: Route one of several inputs to a common output per bank, with switched guard to preserve isolation during low-current measurements.
  • Application: Sequentially connecting instruments to multiple device pins during parametric test, where channel density per slot matters.
  • Technical range: 8-bank and 16-bank 2:1 multiplexer versions, up to 1 A, up to 100 V DC, MS-M style RF connectors, Pickering switched-guard reed relays. Available in PXI.
  • Example modules: 40–121–012 (8x 2:1) and 40–121–011 (16x 2:1). 

Switched Guard General Purpose Relays 

  • Purpose: Provide independent SPST switching with switched guard for direct, flexible signal connection.
  • Application: Low-current WAT and parametric measurements that require discrete, individually controlled switches rather than a fixed matrix or multiplexer topology.
  • Technical range: 13x SPST and 26x SPST versions, up to 1 A, up to 100 V DC, MS-M style RF connectors, Pickering switched-guard reed relays. Available in PXI.
  • Example modules: 40–121–002 (13x SPST) and 40–121–001 (26x SPST).

Selection Aid: Choosing the Right Topology

Use the table below to distinguish the options shown on this page

Module Topology Config Max I Max V DC Connector Platform
40-590-102 Matrix 8x4 0.5 A 150 V MMCX PXI/PXIe
40-590-101 Matrix 16x4 1 A 100 V MMCX PXI/PXIe
40-121-012 Multiplexer 8x 2:1 1 A 100 V MS-M Style RF PXI
40-121-011 Multiplexer 16x 2:1 1 A 100 V MS-M Style RF PXI
40-121-002 General Purpose Relay 13x SPST 1 A 100 V MS-M Style RF PXI
40-121-001 General Purpose Relay 26x SPST 1 A 100 V MS-M Style RF PXI


For larger switching configurations, consider our range of LXI scalable switched-guard matrices.

Quick guidance:

  • Choose a matrix when several instruments must connect flexibly to several test points, and you need PXI/PXIe compatibility with higher voltage headroom.
  • Choose a multiplexer when you need to route one instrument to many device pins in an organized bank structure.
  • Choose general purpose relays when your application calls for individually controlled, discrete switches.

Compatibility and Connectivity

All modules in this range are single-slot PXI or PXIe products and use high-density coaxial connectors to preserve low-leakage driven-guard performance. Because they follow the PXI standard, PXI modules plug into any compliant PXI chassis or a Hybrid slot in a PXIe chassis and can also be hosted in Pickering's LXI/USB modular chassis for remote control over Ethernet or USB. The PXIe modules are compatible with any compliant PXIe chassis.

The 40-590 loop-thru feature interconnects adjacent modules via short, standard cables, allowing you to expand the matrix size without redesigning your switching architecture and supporting test system scalability as your channel count grows.

Software Support

Pickering supplies Windows and Linux drivers free of charge, offering seamless installation and support of all popular Programming languages such as C/C++, LabVIEW™, LabVIEW RT, .NET, VB, LabWindows/CVI, MATLAB®, Python, ATEasy, TestStand™ and Veristand™. For automated signal routing across complex switching, Switch Path Manager helps map and manage paths through these modules, reducing setup time and the risk of connection errors during test development.

Frequently Asked Questions

What isolation resistance do Pickering switched guard modules achieve?

These modules provide isolation resistances up to 10¹³Ω, which is high enough to support accurate low current-driven guard measurements in semiconductor parametric test.

Can I expand the matrix size of these modules?

Yes. The loop-thru functionality lets you interconnect adjacent modules in a chassis using short standard cables, expanding the effective matrix size without adding a separate mainframe.

Are these modules compatible with a PXIe chassis?

The PXI/PXIe matrix modules are available in both formats, and all PXI modules in this range operate in a Hybrid slot of a PXIe chassis. They can also run in a Pickering LXI/USB modular chassis for remote control.

Which module suits wafer acceptance testing?

All modules in this range are designed for WAT and semiconductor parametric test. Choose a matrix for flexible many-to-many connections, a multiplexer for routing one instrument to many pins, or general-purpose relays for discrete switching.

Next Steps

Compare these modules using the specifications and selection table, then confirm the right fit for your test architecture. To design and visualize your signal paths, use Test System Architect to bring configuration, schematic design, cable design, and product selection into a single cohesive workflow.

For application guidance, view the guide on Wafer Acceptance Testing: Leveraging Low-Leakage Switching with Switched Guard Technology. For help matching a module to your requirements, contact Pickering's application engineers.

PXI Low-leakage Switched Guard Switching Solutions | Pickering Interfaces
Untitled Button
Platform
Product Type
Banks
X Size
Y Size
Max I (A)
Max V DC
Connector Type
Price

40-590-102

PXI/PXIe Switched Guard Matrix, 8x4

Matrix module in PXI/PXIe format with switched guard for maximum isolation resistance.

Platform
PXI/PXIe
Product Type
Matrices
X Size
8
Y Size
4
Max I (A)
0.5
Max V DC
150
Connector Type
MMCX
Switch Type
Reed
€3,345

40-121-002

PXI Switched Guard Reed Relay Module, 13x SPST

SPST Switch Module in PXI format with switched guard for maximum isolation resistance

Platform
PXI
Product Type
General Purpose Relays
Max I (A)
1
Max V DC
100
Connector Type
MS-M Style RF
Switch Type
Reed
Relays
13
Relay Contacts
SPST
€3,365

Design and Visualise Test System Signal Paths

Bring system configuration, schematic design, cable design and product selection into a single, cohesive workflow for test system development.

Start designing

Design and Visualise Test System Signal Paths

Design test system switching and signal routing.

40-121-012

PXI Switched Guard Reed Relay Module, 8x 2:1 Multiplexer

2:1 Multiplexer Module in PXI format with switched guard for maximum isolation resistance

Platform
PXI
Product Type
Multiplexers
Banks
8
Max I (A)
1
Max V DC
100
Connector Type
MS-M Style RF
Switch Type
Reed
Channels
2
€3,705

40-590-101

PXI/PXIe Switched Guard Matrix, 16x4

Matrix module in PXI/PXIe format with switched guard for maximum isolation resistance.

Platform
PXI/PXIe
Product Type
Matrices
X Size
16
Y Size
4
Max I (A)
0.5
Max V DC
150
Connector Type
MMCX
Switch Type
Reed
€4,455

40-121-001

PXI Switched Guard Reed Relay Module, 26x SPST

SPST Switch Module in PXI format with switched guard for maximum isolation resistance

Platform
PXI
Product Type
General Purpose Relays
Max I (A)
1
Max V DC
100
Connector Type
MS-M Style RF
Switch Type
Reed
Relays
26
Relay Contacts
SPST
€4,485

40-121-011

PXI Switched Guard Reed Relay Module, 16x 2:1 Multiplexer

2:1 Multiplexer Module in PXI format with switched guard for maximum isolation resistance

Platform
PXI
Product Type
Multiplexers
Banks
16
Max I (A)
1
Max V DC
100
Connector Type
MS-M Style RF
Switch Type
Reed
Channels
2
€4,940

Filter

Platform

PXI modules plug into any cPCI, PXI or PXIe-Hybrid Chassis & our LXI or LXI/USB Modular Chassis. PCI cards plug into the PCI peripheral slots of a PC. LXI products are stand-alone Ethernet controlled solutions.

Product Type

Switch topology or Pickering's programmable resistor products

Banks

The number of independent switch topologies on a single module.

X Size

The number of matrix columns, used with Y Size to specify the size of a cross-point matrix.

Y Size

The number of matrix rows, used with X Size to specify the size of a cross-point matrix.

Max I (A)

Maximum continuous current each switch can carry.

Max V DC

The maximum voltage that may be applied to each switch.