Replacing Relays on a Pickering Module
Pickering Interfaces modules are designed to allow easy repair by a reasonably competent engineer in the field. The relays are generally leaded components that can be extracted using conventional soldering tools. Care must be taken to avoid damage to the PCB when the relay is extracted. The leads of the relay must each be cleared of solder, so the relay is loose in its mounting holes before removal.
Some RF system designs use surface-mount relays, which create fewer discontinuities and tend to improve insertion loss and VSWR. For these designs, surface-mount desoldering tools are required.
For some high-density cards, the relays are very close together, and removing a particular relay may be difficult since there is no access to the relay's sides (because of adjacent relays). In this instance, view the video below, which demonstrates how to remove and replace a relay in situations with limited access.
Replacement relays can be purchased directly from the manufacturer (as specified in the manual or on the device) or through Pickering. For service purposes, we often supply small quantities of relays with faster delivery times compared to the OEM. While some modules include spare relays mounted on the PCB, this is generally not the case for high-density modules. If the spare relays on your module have already been used, we recommend ordering replacements to maintain functionality.
To quickly identify faulty relays, we highly recommend using our eBIRST or BIRST test tools. These tools minimize stress on the PCB by accurately pinpointing faulty relays, preventing misdiagnosis and saving time. Learn more here: eBIRST and BIRST.
In rare instances, the issue may lie elsewhere in the hardware. If so, please feel free to contact us for further assistance.