How a 2-Pole Matrix Works in Switching Systems
There is often confusion about the capabilities of a 2-pole matrix. While each row and column point offers two signal paths, these points are always switched in pairs.
Each crosspoint is controlled by a relay with two independent contacts, both operated by a single control line. These contacts always function in unison—either both are open or both are closed. Any scenario where one contact is open while the other is closed, once settled, is considered a fault condition. For instance, selecting a crosspoint connection between X1 and Y1 will link X1.1 to Y1.1 and X1.2 to Y1.2. It’s important to note that these connections cannot be split.
There are instances where 2-pole switching is achieved using separate relays rather than a single 2-pole relay, typically because the required relay type is not available in a 2-pole configuration. In such cases, the design may ensure both relay coils are controlled by the same input signal, or the software may synchronize the coil drives to function as a single control unit.
Why should you consider using a 2-pole matrix configuration? This setup is particularly useful in several scenarios.
One key application is when you need two pairs of lines, such as in 4-terminal DMM measurements. For instance, in a 4-terminal resistance measurement, you can connect Y1.1 to V+, Y1.2 to I+, Y2.1 to V-, and Y2.2 to I-. This configuration allows for precise and reliable measurements, ensuring optimal performance for your testing needs.
Another example is when switching a voltage source while using remote sensing to ensure proper regulation at the Unit Under Test (UUT). A two-pole configuration guarantees that the sense connection stays aligned with the power connection, maintaining accurate regulation.
Two-pole operation is also advantageous for managing earth currents. By controlling both the flow and return paths of power supply currents, this approach provides greater precision. When combined with sense connections (as in a four-pole configuration), the system gains even better control. Additionally, this switch topology helps minimize signal radiation by effectively managing the antenna's radiating area, reducing unwanted interference.
In certain cases, a source must be connected as a differential system. For such scenarios, the switching system may include a controlled differential line impedance. However, it’s important not to assume that a standard two-pole switch automatically functions as a reliable differential switch. Unless specifically designed for differential signal switching, the transmission line impedance remains uncontrolled.
Switching systems purpose-built for differential operation offer distinct advantages. They generally produce lower electromagnetic emissions and exhibit better crosstalk performance compared to switches designed solely for two-pole operation. This is because differential systems carefully route signal tracks in close proximity while maintaining a greater distance from other signal lines. By doing so, crosstalk induced on one signal line is often mirrored on the other, creating a common-mode signal instead of a differential signal. Additionally, when sufficient separation exists between a victim path and the differential signal, emissions from the differential pair tend to cancel out, reducing interference.
An excellent example of a true differential switching solution is our data communications multiplexer (40-736A).