PXI/PXIe Battery Simulator Modules
Our battery simulator modules emulate the electrical behavior of battery cells, stacks, and power supplies for test and verification. They source current to mimic a battery supply or sink current to mimic a battery under charge, letting you test a device without physical cells. Engineers use them to validate battery management systems (BMS), electric vehicle (EV) systems, portable electronics, and energy storage without the cost, safety risk, or logistical burden of real battery packs.
Most modules fit a standard PXI or PXIe form factor and integrate directly into your existing chassis. High-density channel counts, scalable architectures, and high-isolation voltage barriers enable you to emulate many series-connected cells in a single chassis, making these modules a cost-effective foundation for battery test systems.
What Is a PXI Battery Simulator Module?
A PXI battery simulator module is a programmable power source and sink that reproduces the output characteristics of a battery cell. Rather than charging and discharging physical cells, the module presents a controllable voltage and current at each channel, so your test system sees a realistic battery under a range of conditions.
At a basic level, each channel behaves as an isolated cell. You program the output voltage, and the module either sources current to simulate a battery under load or sinks current to simulate a battery being charged. Multi-channel modules stack these isolated cells in series behind a high-voltage isolation barrier, enabling a single module to emulate a battery stack rather than a single cell.
Engineers reach for these modules during BMS development, functional test, and hardware-in-the-loop applications, where triggering fault conditions or specific cell voltages on real batteries would be slow, expensive, or unsafe.
When Should You Use a Battery Simulator Module?
Use a battery simulator module whenever you need repeatable, controllable battery conditions without the hazards of live cells. Common applications include:
- BMS verification: Set individual cell voltages to test balancing, monitoring, and fault-detection logic.
- Electric vehicle testing: Emulate high-voltage battery stacks using series-connected channels behind a high isolation barrier.
- Portable device testing: Simulate the power supply of cell phones and other battery-powered equipment.
- Energy storage systems: Recreate charge and discharge conditions to validate control electronics.
Battery Simulator Module Families
The PXI battery simulator range covers three product families, each suited to a different application and technical range.
41/43-752A Series: Multi-Channel Battery Stack Emulation
Purpose: Emulate series-connected battery stacks, such as those found in electric vehicles.
Application: BMS test, EV powertrain validation, and high-voltage battery systems.
Technical range: 2, 4, or 6 channels in a single PXI or PXIe slot, with 750 V or 1 kV isolation barriers. Variants offer
voltage and current (V/I) readback and simplified current sink options. Available in both PXI and PXIe.
The high channel density and high isolation-voltage barrier allow you to place many cells in series within a single PXI or LXI chassis, making this the primary choice for battery stack emulation.
41–754 Series: Higher-Current Battery Stack Emulation
Purpose: Emulate battery stacks that require higher per-channel current.
Application: Electric vehicle battery stack testing where greater current sourcing and sinking are needed.
Technical range: 4 channels rated to 5 A, available in both PXI and PXIe, suited to applications that demand more power
per channel than the 752A range.
41–750, 41–751, and 41–753 Series: Single-Cell Simulation
Purpose: Simulate the power supply of a single battery-powered device.
Application: Cell phone testing and other portable, battery-powered equipment.
Technical range: Single channel, up to 6 V DC, with current ratings from 0.25 A (41–751) to 0.5 A (41–750) and 2.8 A
(41–753). The 41–753 also offers programmable output resistance from 0 to 1.15 Ω.
How to Choose the Right Module
Use the checklist below to narrow the range to the models that fit your application.
- Number of cells: Choose a single-channel module (41–750, 41–751, or 41–753) for one battery-powered device, or a multi-channel 752A or 754 module to emulate a series-connected stack.
- Isolation voltage: Select 750 V or 1 kV isolation for the 752A range, depending on the total stack voltage you need to emulate.
- Current requirement: For higher per-channel current, choose the 5 A 41–754 range over the 752A modules.
- Measurement needs: Choose a V/I readback variant if you need to measure the voltage and current at each channel during test.
- Sink requirement: Select a simplified current sink variant where a reduced sink capability meets your charge-simulation needs at lower cost.
| Battery Simulator Family | Channels | Max Voltage | Key Application |
|---|---|---|---|
| 41/43-752A | 2, 4, 6 | Up to 1 kV | Battery stack emulation (EV, BMS) |
| 41/43-754 | 4 | High-current (5 A) | Higher-current stack emulation |
| 41-753 | 1 | 6 V DC | Cell phone and portable device power |
| 41-751 / 41-750 | 1 | 6 V DC | Low-power portable device power |
Software, Connectivity, and Compatibility
All Pickering PXI modules plug into any PXI chassis or a Hybrid slot in a PXIe chassis. They can also be hosted in Pickering's LXI/USB modular chassis, allowing remote control over a Gigabit Ethernet or USB connection. This flexibility lets you deploy the same module across bench, rack, and distributed test systems without changing your core hardware.
The modules ship with a range of Windows and Linux drivers for straightforward integration into your existing test software. Matching cables and connectors are available to speed up system integration and ensure reliable connections to your device under test.