PXI Multiplexer Switch Modules
A PXI multiplexer (MUX) switch module routes multiple input signals to a shared output (or a single input to multiple outputs)
through a single, controllable switching path. Multiplexers typically allow a test system to connect an instrument to
one of many test points, reducing the number of instruments required and simplifying signal routing.
We offer a broad range of PXI and PXIe MUX switch modules for applications ranging from low-voltage signal scanning to
high-power and high-voltage switching. The PXI modules plug into any PXI chassis or a Hybrid slot in a PXIe chassis and can
also be hosted in our LXI/USB modular chassis for
remote control over Gigabit Ethernet or USB. The PXIe modules are compatible with any PXIe chassis.
How Does a PXI Multiplexer Work?
A single-pole MUX connects one common connection to one of many input/output channels at a time via program-controlled relays. Multi-pole MUXes do the same but connect two or more connections between the common and the selected channel simultaneously, and some MUX variants have optional multi-channel selection flexibility whereby multiple channels can be connected simultaneously to the common. High-density versions are available with two or more independent MUX banks on the same module. Engineers use multiplexers when they need to measure or stimulate many signals with a single instrument, such as a digital multimeter (DMM), reading multiple sensor outputs in sequence. Selecting the right module depends on channel count, pole configuration, voltage, and current requirements, and switching technology, e.g., Pickering instrumentation-grade reed relays, electromechanical (EMR), or solid-state relays].
We offer a comprehensive range of in-house manufactured mating cables and connectors for all our modules to help speed up system integration. For more information on PXI topics, visit our Support Knowledgebase or contact us.
PXI Multiplexer Module Families
Each module family below serves a distinct application range, defined by channel density, power handling, and voltage rating.
Low-Density MUX
General-purpose reed relay and EMR multiplexers for routine signal routing and scanning applications. These modules provide between 2 and 64 channels, 1 to 16 banks, and 1 to 8 poles, making them well-suited to general-purpose source and measurement test tasks that require moderate channel counts. We also supply specialized low-thermal EMF (<1.5 uV) and wide-current-range (switching from 10 μA to 2.5 A) MUXes in this category.
High-channel-count reed, EMR, and solid-state multiplexers for applications that require many signal connections in a compact footprint. These modules offer 2 to 198 channels, 1 to 26 banks, and 1 to 160 poles, and include scalable BRIC Large PXI Multiplexers suitable for high-pole-count applications.
Multiplexers designed to switch higher currents and voltages for power-related test applications. These modules provide between 2 and 64 channels, 1 and 8 banks, and 1 and 2 poles, with current ratings up to 40 A and voltages to 400 V
Multiplexers rated for high-voltage signal switching in applications such as battery, automotive, and insulation testing. These modules offer between 2 and 48 channels, 1 to 12 banks, and 1 to 2 poles, with switching up to 1,000 V.
How to Choose the Right PXI Multiplexer
Use the table below to match your application requirements to the appropriate module family.
| Module Family | Channels | Banks | Poles | Key Specification |
|---|---|---|---|---|
| Low Density MUX | 2 to 64 | 1 to 16 | 1 to 8 | General-purpose signal routing |
| High Density MUX | 2 to 198 | 1 to 26 | 1 to 160 | High channel counts, includes BRIC |
| High Power MUX | 2 to 64 | 1 to 8 | 1 to 2 | Up to 40 A current rating |
| High Voltage MUX | 2 to 48 | 1 to 12 | 1 to 2 | Up to 1,000 V switching |
When selecting a module, confirm the following against your test requirements:
- Channel and pole count: Match the number of signals you need to route to the module's channel and pole configuration.
- Voltage and current ratings: Ensure the module's ratings exceed the maximum voltage and current your application will carry.
- Relay technology: Choose reed relays for high reliability and excellent low-signal switching repeatability, electromechanical relays for higher power handling, and solid-state relays for very long life and fast switching.
- Chassis compatibility: All Pickering PXI modules operate in any PXI chassis, a Hybrid slot in a PXIe chassis, or our LXI/USB modular chassis, while our PXIe modules are compatible with any PXIe chassis.
Software and Integration Support
Pickering PXI multiplexer modules ship with a comprehensive range of Windows and Linux drivers, available free of charge. Our drivers support all popular test programming environments, including LabVIEW, C++, .NET, and Python.
To help route signals through complex switching configurations, our Switch Path Manager software automatically operates all required relays given a simple test system endpoint-to-endpoint command. For automated diagnosis of relay failures, our eBIRST switching system test tools provide a fast, straightforward way to locate faults in Pickering PXI switch systems.
Explore our software