PXI Thermocouple Simulators

PXI thermocouple simulators are modular signal sources that generate precise, low-level millivolt outputs to replicate the signals produced by real thermocouples. Test engineers use them to emulate temperature sensors during hardware validation, most commonly in Electronic Control Unit (ECU) testing, without the need for physical heat sources or reference ovens..

Pickering's PXI millivolt thermocouple simulator modules provide 32, 24, 16, or 8 channels of accurate low-voltage sources. Each channel operates across one of three voltage ranges, covering most thermocouple types, including noble and rare metals. This makes them well-suited to sensor emulation in Hardware-in-the-Loop (HIL) applications, where accurate, repeatable stimuli are critical for verifying control system behavior. We also supply connection solutions, including compensation blocks, so you can integrate the simulator into your existing test system with minimal effort.

How Do PXI Thermocouple Simulators Work?

A thermocouple produces a small voltage (typically in the millivolt range) that varies with temperature. A thermocouple simulator reverses this relationship: it outputs a precise millivolt signal that corresponds to a specific simulated temperature.

By connecting a simulator in place of a physical sensor, you can drive an ECU or measurement system through a full range of temperature conditions in software. This removes the cost, delay, and repeatability issues associated with heating and cooling real sensors and lets you exercise fault conditions and edge cases that would be difficult to reproduce with physical hardware.

Pickering's thermocouple simulators install in any compliant PXI chassis or a Hybrid slot in a PXIe chassis and can also be hosted in Pickering's LXI/USB modular chassis for remote control over Ethernet or USB.

Choosing the Right Thermocouple Simulator

Pickering offers two families of thermocouple simulator modules. The right choice depends on whether your channels require isolation and how you plan to configure your voltage ranges.

41–760 Millivolt Thermocouple Simulator

The 41–760 series provides multiple low-voltage sources in a non-isolated design. It's a cost-effective option for applications that don't require channel-to-channel isolation.

  • Purpose: General-purpose thermocouple and low-millivolt sensor simulation
  • Application: ECU testing and sensor emulation where isolation isn't required
  • Channels: 8, 16, 24, or 32
  • Configuration: Selectable voltage ranges covering most thermocouple types

41-761A Analog Output/Thermocouple Simulator

The 41-761A series provides isolated low-voltage outputs configured to a fixed voltage range for each model, delivering consistent performance for both thermocouple simulation and general analog output tasks.

  • Purpose: Isolated thermocouple simulation and precise analog output
  • Application: ECU and sensor emulation requiring a specific, defined output ranged
  • Channels: 8, 16, or 24
  • Configuration: Fixed range per model: ±100mV, ±250mV, ±500mV, ±1000mV, ±1500mV, or ±2000mV

Which Module Should You Choose?

Use the criteria below to match a module family to your application:

Requirement Recommended Family
Lowest cost, no isolation needed 41-760 (Millivolt Simulator)
Channel-to-channel isolation 41-761 (Isolated Millivolt Simulator)
Isolation with a fixed, defined output range 41-761A (Analog Output/Thermocouple Simulator)
Highest channel density (32 channels) 41-760
Selectable voltage ranges across most thermocouple types 41-760 or 41-761

If you're unsure which range best fits your thermocouple types, contact your local Pickering engineer.

Connectivity and Integration

To simplify integration into your test system, Pickering supplies the 40–965–912 Compensation Block for the 41–760 and 41–761 thermocouple simulators. Compensation blocks provide cold-junction compensation, which is essential for accurate thermocouple simulation when interfacing with real measurement hardware.

All Pickering PXI fault insertion modules plug into any compliant PXI chassis or a Hybrid slot in a PXIe chassis and can also be hosted in Pickering's LXI/USB modular chassis for remote control over Ethernet or USB. This flexibility lets you deploy the same module across bench, rack, and distributed test systems without changing your core hardware.

We also supply mating cables and connectors to complete your signal path. For guidance on connectivity, visit our cables and connectors page.

Software and Driver Support

Pickering thermocouple simulators are supported by our comprehensive range of Windows and Linux drivers, available for free download. Our simulation software, included with the PXI driver installation, lets you develop and verify test system software independently of the physical hardware. This means your test program development can begin before modules arrive, reducing overall project lead time.

Frequently Asked Questions

What's the difference between isolated and non-isolated thermocouple simulators?

Non-isolated modules, such as the 41–760 series, share a common ground across channels and offer a lower-cost solution. Isolated modules, such as the 41–761 and 41-761A series, provide electrically independent channels that prevent ground loops and common-mode interference, which is important in applications where channels connect to separate reference points.

Which thermocouple types do Pickering simulators support?

They support all standard thermocouple types, including J, K, T, E, N, R, S, and B.

How do they support so many different types?

The modules act as highly accurate programmable millivolt sources. They output low-voltage ranges (±20mV, ±50mV, and ±100mV) that precisely match standard sensor voltage curves.

Do I need to manually calculate the millivolt conversions in my code?

No. Pickering’s software drivers (for LabVIEW, Python, C#, etc) automatically convert temperature values into the correct millivolt outputs using standard NIST lookup tables.

Can these simulators test for broken or damaged wiring?

Yes. The modules feature built-in open-circuit simulation to test how your data acquisition unit or ECU responds to sensor faults.

Do thermocouple simulators require cold-junction compensation?

Accurate thermocouple simulation requires cold-junction compensation when interfacing with real measurement hardware. Pickering supplies the 40–965–912 Compensation Block for use with the 41–760 and 41–761 series to address this need.

PXI Thermocouple Simulators | Sensor Emulation Modules
Untitled Button
Channels
Price

40-965-912

Compensation Block for Thermocouple Simulator Modules

Compensation Block for 41-760 & 41-761 Thermocouple Simulators

€820

41-760-004

PXI Millivolt Thermocouple Simulator Module - 8 Channel

Provides multiple low-voltage sources ideal for the simulation of thermocouples

Channels
8
Product Type
Thermocouple Simulator
€2,415

Design and Visualise Test System Signal Paths

Bring system configuration, schematic design, cable design and product selection into a single, cohesive workflow for test system development.

Start designing

Design and Visualise Test System Signal Paths

Design test system switching and signal routing.

41-761-004

PXI Isolated Millivolt Thermocouple Simulator - 8 Channel

Provides multiple isolated low voltage sources ideal for the simulation of thermocouples

Channels
8
Product Type
Thermocouple Simulator
€3,485

41-760-003

PXI Millivolt Thermocouple Simulator Module - 16 Channel

Provides multiple low-voltage sources ideal for the simulation of thermocouples

Channels
16
Product Type
Thermocouple Simulator
€3,455

41-760-002

PXI Millivolt Thermocouple Simulator Module - 24 Channel

Provides multiple low-voltage sources ideal for the simulation of thermocouples

Channels
24
Product Type
Thermocouple Simulator
€4,515

41-761-003

PXI Isolated Millivolt Thermocouple Simulator - 16 Channel

Provides multiple isolated low voltage sources ideal for the simulation of thermocouples

Channels
16
Product Type
Thermocouple Simulator
€4,970

41-760-001

PXI Millivolt Thermocouple Simulator Module - 32 Channel

Provides multiple low voltage sources ideal for the simulation of thermocouples

Channels
32
Product Type
Thermocouple Simulator
€5,555

41-761-002

PXI Isolated Millivolt Thermocouple Simulator - 24 Channel

Provides multiple isolated low voltage sources ideal for the simulation of thermocouples

Channels
24
Product Type
Thermocouple Simulator
€6,460

41-761-001

PXI Isolated Millivolt Thermocouple Simulator - 32 Channel

Provides multiple isolated low voltage sources ideal for the simulation of thermocouples

Channels
32
Product Type
Thermocouple Simulator
€7,955

41-761A-001

PXI Analog Output/Thermocouple Simulator - 32 Channel, ±100mV

Provides isolated low voltage outputs for precise thermocouple and sensor simulation

Channels
32
Product Type
Thermocouple Simulator
Platform
PXI

41-761A-002

PXI Analog Output/Thermocouple Simulator - 24 Channel, ±100mV

Provides isolated low voltage outputs for precise thermocouple and sensor simulation

Channels
24
Product Type
Thermocouple Simulator
Platform
PXI

41-761A-003

PXI Analog Output/Thermocouple Simulator - 16 Channel, ±100mV

Provides isolated low voltage outputs for precise thermocouple and sensor simulation

Channels
16
Product Type
Thermocouple Simulator
Platform
PXI

41-761A-004

PXI Analog Output/Thermocouple Simulator - 8 Channel, ±100mV

Provides isolated low voltage outputs for precise thermocouple and sensor simulation

Channels
8
Product Type
Thermocouple Simulator
Platform
PXI

41-761A-101

PXI Analog Output/Thermocouple Simulator - 32 Channel, ±250mV

Provides isolated low voltage outputs for precise thermocouple and sensor simulation

Channels
32
Product Type
Thermocouple Simulator
Platform
PXI

41-761A-102

PXI Analog Output/Thermocouple Simulator - 24 Channel, ±250mV

Provides isolated low voltage outputs for precise thermocouple and sensor simulation

Channels
24
Product Type
Thermocouple Simulator
Platform
PXI

41-761A-103

PXI Analog Output/Thermocouple Simulator - 16 Channel, ±250mV

Provides isolated low voltage outputs for precise thermocouple and sensor simulation

Channels
16
Product Type
Thermocouple Simulator
Platform
PXI

41-761A-104

PXI Analog Output/Thermocouple Simulator - 8 Channel, ±250mV

Provides isolated low voltage outputs for precise thermocouple and sensor simulation

Channels
8
Product Type
Thermocouple Simulator
Platform
PXI

41-761A-201

PXI Analog Output/Thermocouple Simulator - 32 Channel, ±500mV

Provides isolated low voltage outputs for precise thermocouple and sensor simulation

Channels
32
Product Type
Thermocouple Simulator
Platform
PXI

41-761A-202

PXI Analog Output/Thermocouple Simulator - 24 Channel, ±500mV

Provides isolated low voltage outputs for precise thermocouple and sensor simulation

Channels
24
Product Type
Thermocouple Simulator
Platform
PXI

41-761A-203

PXI Analog Output/Thermocouple Simulator - 16 Channel, ±500mV

Provides isolated low voltage outputs for precise thermocouple and sensor simulation

Channels
16
Product Type
Thermocouple Simulator
Platform
PXI

41-761A-204

PXI Analog Output/Thermocouple Simulator - 8 Channel, ±500mV

Provides isolated low voltage outputs for precise thermocouple and sensor simulation

Channels
8
Product Type
Thermocouple Simulator
Platform
PXI

41-761A-301

PXI Analog Output/Thermocouple Simulator - 32 Channel, ±1000mV

Provides isolated low voltage outputs for precise thermocouple and sensor simulation

Channels
32
Product Type
Thermocouple Simulator
Platform
PXI

41-761A-302

PXI Analog Output/Thermocouple Simulator - 24 Channel, ±1000mV

Provides isolated low voltage outputs for precise thermocouple and sensor simulation

Channels
24
Product Type
Thermocouple Simulator
Platform
PXI

Filter

Channels

The number of discrete channels in a single topology.

Loading
Beta

How can I help?

Hi , I'm TESS - your friendly AI agent

Press Enter to submit

TESS is a moderated, AI agent. TESS can make mistakes, please verify important information independently.


Chat history

Log in or create an account to save & continue your chats with TESS.

Log in

or create an account